Decrease of resistance to air flow with nasal strips as measured with the airflow perturbation device

نویسندگان

  • Lily S Wong
  • Arthur T Johnson
چکیده

BACKGROUND Nasal strips are used by athletes, people who snore, and asthmatics to ease the burden of breathing. Although there are some published studies that demonstrate higher flow with nasal strips, none had directly measured the effect of the strips on nasal resistance using the airflow perturbation device (APD). The APD is an inexpensive instrument that can measure respiratory resistance based on changes in mouth pressure and rate of airflow. METHOD This study tested forty-seven volunteers (14 men and 33 women), ranging in age from 17 to 51. Each volunteer was instructed to breathe normally into the APD using an oronasal mask with and without nasal strips. The APD measured respiratory resistance during inhalation, exhalation, and an average of the two. RESULTS Results of a paired mean t-test comparing nasal strip against no nasal strip were statistically significant at the p = 0.05 level. The Breathe Right nasal dilator strips lowered nasal resistance by an average of 0.5 cm H20/Lps from an average nasal resistance of 5.5 cm H20/Lps. CONCLUSIONS Nasal strips reduce nasal resistance when measured with the APD. The effect is equal during exhalation and during inhalation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active anterior rhinomanometric (AAR) evaluation of nasal airway resistance in normal Iranian sample

  Abstract:   Background: The most important and complex phenomenon of respiratory function of the nose is related to different nasal anatomy. The differences in facial anatomic structure between different races may also be reflected in nasal resistance and airflow. Caucasians has different facial anatomic structure which is the reflection of intranasal resistance or consequence of airflow. The...

متن کامل

A Comparison of Over-the-Counter Mechanical Nasal Dilators: A Systematic Review.

IMPORTANCE The internal nasal valve is the narrowest part of the nasal airway and a common site of inspiratory collapse and obstruction of nasal airflow. Over-the-counter mechanical nasal dilators are an alternative to surgical intervention that attempts to improve airflow through the internal nasal valve. OBJECTIVE To determine the efficacy of over-the-counter mechanical nasal dilators and c...

متن کامل

DDT Issue1 Oct '02

Transportation and deposition of droplets from a nebulizer within the nasal cavity are dependent on the existing airflow patterns. Figure 1 illustrates the inspired air profile, which is the dominant airflow pattern in the cavity. Inspired air patterns largely determine where and how drug deposition in the nasal cavity occurs. Relatively low flow amounts are observed in the olfactory region (<1...

متن کامل

Respiratory resistance measured by an airflow perturbation device.

The airflow perturbation device (APD) is an instrument for the measurement of respiratory resistance. The APD is small, lightweight, fast and requires no special breathing manoeuvres. Airflow perturbation determines resistance by superimposing a periodic signal onto spontaneous breathing with a variable resistance device. Respiratory impedance is the ratio of magnitude of pressure perturbation ...

متن کامل

Measuring oral and nasal airflow in production of Chinese plosive

This study reports a new integrated device for measuring oral and nasal airflow with lossless speech recording with preliminary results on Chinese plosives. An acoustically transparent fiber-made mask acts both as a material for airflow resistance and a support for partitioning oral and nasal chambers. Two pressure sensors placed directly on the mask measure air pressure signals that correspond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2004