Refractive Results Using a New Optical Biometry Device

نویسندگان

  • Serdar Aktas
  • Hatice Aktas
  • Mehmet Tetikoglu
  • Hacı Murat Sagdık
  • Fatih Özcura
  • Patrick Wall.
چکیده

The aim of the study was to compare the measurements of optical (AL-Scan; Nidek Co., Ltd.) and ultrasonic (Echo Scan US-800; Nidek Co., Ltd.) biometry devices and to assess refractive results after cataract surgery. Eighty-one cataractous eyes of 81 patients were included in this study. Biometry was performed using the AL-Scan and an ultrasonic biometer (USB). Axial length (AL), keratometry (K) data, and intraocular lens (IOL) power calculations using the SRK/T formula were compared. Bland-Altman analysis was used to assess the extent of agreement between AL-Scan and USB data in terms of AL measurement and IOL power calculation. The K measurements of the AL-Scan were compared to autorefractor data (Canon Autorefractor RK-F1). The AL-Scan assessed the AL as longer (average difference 0.06 ± 0.18 mm; ICC = 0.987; P < 0.001) and the IOL power as greater (average difference 0.19 ± 0.66 D; ICC = 0.964; P < 0.001) than the USB. The AL-Scan also measured average K values (average difference 0.25 ± 0.25 D; ICC = 0.985; P < 0.001) greater than those given by the autorefractor. The postoperative mean absolute error was +0.30 ± 0.04 D (minimum: -0.51 D, maximum +1.04 D). The postoperative mean K value change was 0.36 ± 0.29 D (P < 0.05). The differences between measurements afforded by the AL-Scan and USB may be clinically acceptable. Keratometric changes that develop after cataract operations compromise the attainment of good refractive outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometer.

PURPOSE To compare the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power obtained with a new optical biometer (AL-Scan) and a standard optical biometer (IOLMaster 500). SETTING Siriraj Hospital, Mahidol University, Bangkok, Thailand. DESIGN Prospective comparative study. METHODS Two independent operators measured eyes with cataract using both biometers....

متن کامل

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Pa...

متن کامل

SCIENTIFIC REPORT IOLMaster biometry: refractive results of 100 consecutive cases

Aims: To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. Methods: The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...

متن کامل

IOLMaster biometry: refractive results of 100 consecutive cases.

AIMS To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. METHODS The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...

متن کامل

مقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت

Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015