Astigmatism correction with toric IOL: analysis of visual performance, position, and wavefront error.

نویسندگان

  • Lisa Toto
  • Luca Vecchiarino
  • Erminia D'Ugo
  • Daniela Cardone
  • Alessandra Mastropasqua
  • Rodolfo Mastropasqua
  • Marta Di Nicola
چکیده

PURPOSE To evaluate astigmatism correction, visual performance, intraocular lens (IOL) position, and wavefront error after implantation of toric IOLs in patients with cataract. METHODS This prospective study comprised 30 eyes of 30 patients with cataract who were candidates for phacoemulsification and implantation of the AcrySof toric IOL (Alcon Laboratories, Inc., Fort Worth, TX). Mean preoperative corneal keratometric and subjective refractive cylinder were 2.10 ± 0.47 and 2.17 ± 0.41 diopters (D), respectively. RESULTS The refractive cylinder decreased significantly from 2.17 ± 0.41 to 0.73 ± 0.45 D (P = .001) at 180 days postoperatively. The difference between preoperative corneal astigmatism and postoperative refractive astigmatism was statistically significant (P < .05). At 180 days postoperatively, the uncorrected distance visual acuity was 0.20 logMAR (Snellen 20/32) in 100% of patients and 0.0 logMAR (Snellen 20/20) in 64% of patients. The root mean square of internal coma and trefoil aberrations showed a trend toward reduction; internal spherical aberration significantly decreased, whereas corneal trefoil aberration significantly increased (P < .05). A low amount of IOL decentration and tilt were detected at 30 and 180 days postoperatively, respectively. CONCLUSIONS Toric IOL implantation is an effective procedure for correction of preexisting corneal astigmatism, improving visual performance, and inducing a low amount of higher-order aberrations. Moreover, the toric IOLs is well positioned early after surgery and stable over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation.

PURPOSE To present case examples outlining the use of wavefront aberrometry for toric intraocular lens (IOL) implantation pre- and postoperatively. METHODS Twelve eyes that underwent AcrySof Toric IOL (Alcon Inc Laboratories) implantation were assessed pre- and postoperatively using the NIDEK OPD Scan II (NIDEK Co Ltd). Wavefront aberrometry, corneal topography, and objective visual quality w...

متن کامل

Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

IMPORTANCE Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. OBJECTIVE To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism...

متن کامل

The influence of incision-induced astigmatism and axial lens position on the correction of myopic astigmatism with the Artisan toric phakic intraocular lens.

PURPOSE To evaluate postoperative astigmatism with regard to incision-induced astigmatism and deviation in axial alignment with the use of preoperative limbal marking with the Javal keratometer (Haag Streit, Bern, Switzerland) in eyes implanted with the Artisan toric phakic intraocular lens (IOL) (Ophtec, Groningen, The Netherlands). DESIGN Prospective nonrandomized trial. PARTICIPANTS Fift...

متن کامل

Stability of a three-piece silicone intraocular lens implanted in the capsular bag

odern cataract surgery aims not only to remove lens opacities but also to achieve correction of any refractive error. In addition to restoration of uncorrected visual acuity, correction of preexisting astigmatism is also important, and treatment options for this purpose include corneal limbal relaxing incisions, excimer laser photoablation and toric intraocular lens (IOL) implantation. Shimizu ...

متن کامل

Vector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.

PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 2013