Ocular biomechanics: measurement parameters and terminology.
نویسندگان
چکیده
doi:10.3928/1081597X-20110519-01 T raditionally, biomechanical properties of the cornea have been assessed in vitro by measuring stress-strain and Young modulus on corneal strips. In 2005, the Ocular Response Analyzer (ORA; Reichert Technologies, Depew, New York) was launched as the fi rst commercial device claiming to provide in vivo measurements of corneal biomechanics.1 It utilizes a dynamic bi-directional applanation process in which two applanation pressure measurements are recorded: one while the cornea is moving inward, and the other as the cornea returns. The primary output measurements are Goldmann-correlated intraocular pressure (IOPg), and a new parameter called corneal hysteresis (CH), defi ned by Reichert as the difference between the two pressure values of the inward and outward applanations. The ORA provides two additional new parameters: corneal-compensated intraocular pressure (IOPcc) and corneal resistance factor (CRF), which was thought to be an indicator of the overall “resistance” of the cornea. Given the promising nature of the possibility of measuring biomechanics in vivo, many studies covering a wide range of topics have been performed and published using the ORA in the past 5 years. The majority of articles addressed the following topics: 1) IOP, CH, and CRF measurements in patients with glaucoma, 2) changes in CH and CRF after corneal refractive surgery, and 3) changes in CH and CRF in keratoconic patients and the possibility of using CH and CRF for assisting in the detection of early keratoconus. With this initial body of articles published, we can now start to evaluate the clinical utility of the ORA in refractive surgery. This editorial reviews the use of the ORA for measuring IOP, CH, CRF, and future parameters and discusses the commonly used terminology. IOP MEASUREMENTS Corneal-compensated IOP has been shown to be comparable to IOP measured with dynamic contour tonometry,2 and IOPcc has also been shown to be independent of central corneal thickness.3 Therefore, as the proportion of patients electing to have corneal refractive surgical procedures continues to increase, IOPcc will remain a valid and powerful tool to diagnose and monitor patients with glaucoma after corneal surgery.
منابع مشابه
Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea
Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The ...
متن کاملComprehensive evaluation of dehydration impact on ocular tissue during Ramadan fasting
Purpose: The present study aimed to review the effect of dehydration during Ramadan fasting on the health and ocular parameters leading to changes in eye function. Methods: Articles included in the study were taken from Pub Med, Ovid, Web of Science and Google Scholar up to 2014.Related articles were also obtained from scientific journals in fasting and eye. Results: Dehydration and nutrition c...
متن کاملCorneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature
The Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Buffalo, NY) allows direct measurement of corneal biomechanical properties. Since its introduction, many studies have sought to elucidate the clinical applications of corneal hysteresis (CH) and corneal resistance factor (CRF). More recently, detailed corneal deformation signal waveform analysis (WA) has potentially expanded t...
متن کاملExamination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery.
PURPOSE To analyze the early results of a new device measuring ocular biomechanics after corneal refractive surgery. PATIENTS AND METHODS Thirty nine refractive surgery patients were enrolled in the study (age: 32.6±9.9 years). Laser in situ keratomileusis (LASIK) was performed on 52 eyes of 26 patients and photorefractive keratectomy (PRK) was done on 26 eyes of 13 patients. Ten device-speci...
متن کاملInvestigation of the effects of Islamic fasting on ocular parameters
Purpose To investigate the effects of religious fasting during the month of Ramadan on intraocular pressure (IOP), refractive error, corneal tomography and biomechanics, ocular biometry, and tear film layer properties. Methods This prospective study was carried out one week before and in the last week of Ramadan. Ninety-four eyes of 94 healthy adult volunteers (54 males and 40 females) with a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2011