Resonant ultrasound spectroscopy of cylinders over the full range of Poisson's ratio.

نویسندگان

  • Tim Jaglinski
  • Roderic S Lakes
چکیده

Mode structure maps for freely vibrating cylinders over a range of Poisson's ratio, ν, are desirable for the design and interpretation of experiments using resonant ultrasound spectroscopy (RUS). The full range of isotropic ν (-1 to +0.5) is analyzed here using a finite element method to accommodate materials with a negative Poisson's ratio. The fundamental torsional mode has the lowest frequency provided ν is between about -0.24 and +0.5. For any ν, the torsional mode can be identified utilizing the polarization sensitivity of the shear transducers. RUS experimental results for materials with Poisson's ratio +0.3, +0.16, and -0.3 and a previous numerical study for ν = 0.33 are compared with the present analysis. Interpretation of results is easiest if the length∕diameter ratio of the cylinder is close to 1. Slight material anisotropy leads to splitting of the higher modes but not of the fundamental torsion mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resonant ultrasound spectroscopy of cubes over the full range of Poisson's ratio.

Methods are developed for study of isotropic cubes via resonant ultrasound spectroscopy. To that end, mode structure maps are determined for freely vibrating isotropic cubes via finite element method over the full range of Poisson's ratio ν (-1 to +0.5). The fundamental torsional mode has the lowest frequency provided ν is between about -0.31 and +0.5. Experimental measurements for the mode str...

متن کامل

Contribution of dislocation dipole structures to the acoustic nonlinearity

Related Articles Microparticle trapping in an ultrasonic Bessel beam Appl. Phys. Lett. 99, 233704 (2011) The study of new vacuum pressure measurement technique using ultrasonic acoustic impedance transducers Rev. Sci. Instrum. 82, 075111 (2011) Resonant ultrasound spectroscopy of cylinders over the full range of Poisson's ratio Rev. Sci. Instrum. 82, 035105 (2011) A novel method for digital ult...

متن کامل

The Elasticity Coefficients Measurement of Human Dentin Based on RUS

This paper proposed to take advantages of resonant ultrasound spectroscopy (RUS) to measure the mechanical properties of human dentin specimen. The resonant spectroscopy of the dentin specimen was obtained between the frequency bands 155 and 575 kHz, and resonant frequencies were extracted by linear predictive filter and then by Levenberg-Marquardt method. By inverse problem approach, 13 experi...

متن کامل

Resonant ultrasound spectroscopy measurements of the elastic constants of human dentin.

The technique of resonant ultrasound spectroscopy (RUS) was used to measure the second-order elastic constants of hydrated human dentin. Specimens were placed between two transducers, and the resonant frequencies of vibration were measured between 0.5 and 1.4 MHz. The elastic constants determined from the measured resonant frequencies in hydrated dentin exhibited slight hexagonal anisotropy, wi...

متن کامل

A unit cell structure with tunable Poisson ' s ratio from positive to negative

A novel unit cell structure with re-entrant hollow skeleton is designed and its Poisson's ratio has been studied using the finite element method (FEM) as a function of the geometric variables and the parent material Poisson's ratio. The simulation results showed that the Poisson's ratio of the unit cell structure is tunable over the full range of Poisson’s ratio (-1 to +0.5) by varying the geom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 2011