Multicenter evaluation of AMPLICOR and automated COBAS AMPLICOR CT/NG tests for Neisseria gonorrhoeae.
نویسندگان
چکیده
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for their ability to detect Neisseria gonorrhoeae infections. Test performance compared to that of culturing was evaluated for 2,192 matched endocervical swab and urine specimens obtained from women and for 1, 981 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a confirmatory PCR test for an alternative target sequence within the N. gonorrhoeae 16S rRNA gene were considered to be true positives. The overall prevalences of gonorrhea were 6.6% in women and 20.1% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.8% of the specimens and exhibited virtually identical sensitivities and specificities. The results that follow are for the COBAS AMPLICOR format. With the infected patient as the reference standard, the resolved sensitivities of PCR were 92.4% for endocervical swab specimens and 64.8% for female urine specimens. There were no significant differences in these rates between women with and without symptoms. Among symptomatic men, COBAS AMPLICOR sensitivities were 94.1% for urine and 98.1% for urethral swabs; for asymptomatic men, the results were 42.3 and 73.1%, respectively. In comparison, the sensitivities of culturing were 84.8% for endocervical specimens, 92.7% for symptomatic male urethral specimens, and only 46.2% for urethral specimens obtained from asymptomatic men. When PCR results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.5% for endocervical swab specimens, 99.8% for female urine specimens, 98.9% for male urethral swab specimens, and 99.9% for male urine specimens. The internal control revealed that 2.1% of specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 99.2% of specimens because 60.0% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR CT/NG test for N. gonorrhoeae exhibited high sensitivity and specificity with urethral swab and urine specimens from men and endocervical swab specimens from women and thus is well suited for diagnosing and screening for N. gonorrhoeae infection.
منابع مشابه
Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China
BACKGROUND To evaluate the performance of the Abbott RealTime CT/NG assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) among female sex workers (FSWs) in China. METHODS Cervical swabs from 997 participants were blindly detected by the Abbott RealTime CT/NG assay on the automated m2000 molecular platform and Roche Cobas Amplicor CT/NG assay. Discrepant analysis we...
متن کاملMulticenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis.
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-n...
متن کاملDetection of Chlamydia trachomatis and Neisseria gonorrhoeae in an STI population: performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor with urine specimens and urethral/cervicovaginal samples
OBJECTIVES This study assessed the performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor for Chlamydia trachomatis and Neisseria gonorrhoeae detection. DESIGN A cross-sectional study design. SETTING Izore, Centre for Diagnosing Infectious Diseases in Friesland, the Netherlands, tested samples sent from regional sexually transmitted infection (STI) outp...
متن کاملEvaluation of real time polymerase chain reaction assays for confirmation of Neisseria gonorrhoeae in clinical samples tested positive in the Roche Cobas Amplicor assay.
OBJECTIVE Development of a rapid, sensitive, and accurate assay for confirmation of Neisseria gonorrhoeae in clinical samples. METHOD Two real time polymerase chain reaction (PCR) assays, developed on the LightCycler for amplification of the N gonorrhoeae cppB gene, were utilised for confirmation of this bacterial pathogen in samples positive by the Roche Cobas Amplicor assay. Performance cha...
متن کاملNeisseria species identification assay for the confirmation of Neisseria gonorrhoeae-positive results of the COBAS Amplicor PCR.
Screening assays for Neisseria gonorrhoeae exhibit low positive predictive values, particularly in low-prevalence populations. A new real-time PCR assay that detects and identifies individual Neisseria spp. using melt curve analysis was compared to two previously published supplementary assays. NsppID, a 16S rRNA real-time PCR/melt curve assay developed to distinguish N. gonorrhoeae from other ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 38 10 شماره
صفحات -
تاریخ انتشار 2000