Preoxygenated hemoglobin-based oxygen carrier HBOC-201 annihilates myocardial ischemia during brief coronary artery occlusion in pigs.

نویسندگان

  • Maaike Te Lintel Hekkert
  • Gregory P Dubé
  • Evelyn Regar
  • Martine de Boer
  • Pascal Vranckx
  • Wim J van der Giessen
  • Patrick W Serruys
  • Dirk J Duncker
چکیده

Because of their ability to perfuse remote regions and deliver oxygen, hemoglobin-based oxygen carriers (HBOCs) may be considered in the treatment of several ischemic conditions such as acute coronary syndromes or high-risk percutaneous intervention. Here we studied the effects of intracoronary infusion of ex vivo preoxygenated HBOC-201 during brief total coronary artery occlusion (CAOs) on myocardial oxygenation and left ventricular (LV) function in a large animal model and investigated the influence of HBOC-201 temperature and infusion rate on these effects. Thirteen open-chest anesthetized swine were instrumented for measurement of global and regional LV function and metabolism. CAOs were induced by inflating an intracoronary balloon catheter; preoxygenated HBOC-201 (12 g/dL) was infused distally through the central lumen of the balloon catheter. Animals underwent consecutive 3-min CAOs interspersed by 30 min of reperfusion, accompanied by different HBOC-201 infusion rates (0, 15, 23, 30, 40, and 50 ml/min) and/or two infusion temperatures (18 degrees C or 37 degrees C) in random order. CAO elicited immediate loss of systolic shortening (SS) in the ischemic region (19 +/- 1% at baseline vs. -3 +/- 2% at end of CAO), resulting in decreases in maximum rate of rise in LV pressure (15 +/- 5%) and stroke volume (12 +/- 4%; all P < 0.05). Balloon deflation resulted in marked coronary reactive hyperemia (to 472 +/- 74% of baseline), increases in coronary venous concentrations of adenosine + inosine (to 218 +/- 26% of baseline; both P < 0.05) and rapid restoration of SS toward baseline. HBOC-201 ameliorated the CAO-induced changes in SS, stroke volume, reactive hyperemia, and coronary venous adenosine + inosine. The effects were temperature and flow dependent with full preservation of SS at 50 ml/min HBOC-201 of 37 degrees C. In conclusion, intracoronary preoxygenated HBOC-201 preserved myocardial oxygenation and LV function in swine during CAO in a dose- and temperature-dependent manner. In our study setting, preoxygenated HBOC-201 can match the oxygen delivery role of endogenous blood in the heart on an almost equivalent-volume basis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A polymerized bovine hemoglobin oxygen carrier preserves regional myocardial function and reduces infarct size after acute myocardial ischemia.

The purpose of this study was to test if HBOC-201, a hemoglobin-based oxygen-carrying solution, can decrease infarct size (or Inf) during acute, severe myocardial ischemia and reperfusion. To test the impact of HBOC-201 on infarct size, ischemia was produced in 18 dogs by coronary stenosis to achieve 80-95% flow reduction for 195 min along with pacing 10% above the spontaneous heart rate, follo...

متن کامل

A hemoglobin based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus Hetastarch (HEX) in an uncontrolled liver injury hemorrhagic shock swine model with delayed evacuation.

BACKGROUND As HBOC-201 improves outcome in animals with hemorrhagic shock (HS), we compared HBOC-201 and HEX (used by U.S. military special operations forces) in a swine model of delayed evacuation and uncontrolled HS. METHODS Twenty-four Yucatan pigs underwent a grade III liver injury and were resuscitated with HBOC-201, HEX, or no fluid (NON). Additional infusions were given for hypotension...

متن کامل

Administration of bovine polymerized haemoglobin before and during coronary occlusion reduces infarct size in rabbits.

BACKGROUND Haemoglobin-based oxygen carriers (HBOC) seem to increase the risk of mortality and myocardial infarction in clinical trials. Therefore, we designed this randomized placebo-controlled animal study to evaluate the effects of prophylactic and therapeutic administration of HBOC in a myocardial ischaemia-reperfusion model with respect to infarct size and areas of impaired perfusion (no r...

متن کامل

A bovine hemoglobin-based oxygen carrier as pump prime for cardiopulmonary bypass: reduced systemic lactic acidosis and improved cerebral oxygen metabolism during low flow in a porcine model.

OBJECTIVES Cerebral ischemia can occur during cardiopulmonary bypass, especially during low flow. HBOC-201 (OPK Biotech, Cambridge, Mass) is a hemoglobin-based oxygen-carrying solution that enhances oxygen delivery. This project evaluated the benefits on total body and cerebral oxygen delivery and consumption using HBOC-201 during cardiopulmonary bypass. METHODS Twelve immature swine were ass...

متن کامل

Differential sensitivities of pulmonary and coronary arteries to hemoglobin-based oxygen carriers and nitrovasodilators: study in a bovine ex vivo model of vascular strips.

Vasoconstriction is a major adverse effect of first and second generation hemoglobin-based oxygen carriers (HBOCs) that hinders their development as blood substitute. However, intravenous infusion of HBOC-201 (second generation) to patients induces significant pulmonary hypertension without significant coronary vasoconstriction. We compared contractile responses of isolated bovine pulmonary and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 298 3  شماره 

صفحات  -

تاریخ انتشار 2010