Methotrexate loaded SAE coated coronary stents reduce neointimal hyperplasia in a porcine coronary model.

نویسندگان

  • Y Huang
  • K Salu
  • X Liu
  • S Li
  • L Wang
  • E Verbeken
  • J Bosmans
  • I De Scheerder
چکیده

OBJECTIVE To evaluate the effect of stent based methotrexate delivery on neointimal hyperplasia. METHODS Stainless steel coronary stents and biological polymer coated (SAE) stents were randomly implanted in coronary arteries of pigs with a stent to artery ratio of 1.1:1. The pigs were killed after five days (10 stents) or four weeks (20 stents). Second, stainless steel coronary stents were dip coated in a 10 mg/ml methotrexate-SAE polymer solution, resulting in a total load of 150 microg methotrexate/stent. SAE coated stents and methotrexate loaded stents were randomly implanted in porcine coronary arteries with a stent to artery ratio of 1.2:1 and followed up to four weeks. RESULTS SAE coated stents and bare stents elicited a similar tissue response at five days. At four weeks, neointimal hyperplasia induced by the coated stents was less pronounced than with the bare stents (1.32 (0.66) v 1.73 (0.93) mm2, p > 0.05). In vitro drug release studies showed that 50% of the methotrexate was released in 24 hours, and all drug was released within four weeks. No impact on vascular smooth muscle cell proliferation or viability was observed in in vitro cell cultures. At four weeks the arteries with methotrexate loaded stents had decreased peristrut inflammation and neointimal hyperplasia (1.22 (0.34) v 2.25 (1.28) mm2, p < 0.01). CONCLUSIONS SAE coating had an excellent biocompatibility with vascular tissue. Stent based delivery of methotrexate in the SAE coating effectively reduced neointimal hyperplasia in a porcine coronary stent model, potentially due to reduced peristrut inflammation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.

BACKGROUND Biodegradable polymer-coated stents may have positive effects on arterial healing, and reduce the need for prolonged antiplatelet therapy. AIM To assess the vascular effects of the biodegradable polymer proposed as a stent coating, as well as to evaluate inhibition of intimal hyperplasia by Biodegradable Polymer-Coated Paclitaxel-Eluting Stents (BP-PES, LUC-Chopin, Balton) in porci...

متن کامل

Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis.

BACKGROUND Despite limiting elastic recoil and late vascular remodeling after angioplasty, coronary stents remain vulnerable to restenosis, caused primarily by neointimal hyperplasia. Paclitaxel, a microtubule-stabilizing drug, has been shown to inhibit vascular smooth muscle cell migration and proliferation contributing to neointimal hyperplasia. We tested whether paclitaxel-coated coronary st...

متن کامل

Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model.

BACKGROUND The purpose of this study was to determine the efficacy of stent-based delivery of sirolimus (SRL) alone or in combination with dexamethasone (DEX) to reduce in-stent neointimal hyperplasia. SRL is a potent immunosuppressive agent that inhibits SMC proliferation by blocking cell cycle progression. METHODS AND RESULTS Stents were coated with a nonerodable polymer containing 185 micr...

متن کامل

Human recombinant activated protein C-coated stent for the prevention of restenosis in porcine coronary arteries

Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in ...

متن کامل

Anti-inflammatory Effect of Abciximab-Coated Stent in a Porcine Coronary Restenosis Model

The aim of this study was to examine the anti-inflammatory effect of abciximab-coated stent in a porcine coronary overstretch restenosis model. Ten abciximab-coated stents, ten sirolimus-eluting stents (SES), and ten paclitaxel-eluting stents (PES) were deployed with oversizing (stent/artery ratio 1.3:1) in porcine coronary arteries, and histopathologic analysis was done at 28 days after stenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2004