Active compression-decompression CPR improves vital organ perfusion in a dog model of ventricular fibrillation.
نویسندگان
چکیده
OBJECTIVES This study was designed to assess whether a new method of cardiopulmonary resuscitation (CPR), termed active compression-decompression CPR, or ACD-CPR, improves organ perfusion when compared with standard (S) CPR in a dog model of ventricular fibrillation. BACKGROUND ACD-CPR has recently been shown to improve hemodynamic and respiratory parameters during cardiac arrest when compared with standard CPR. However, to our knowledge, the effects of ACD-CPR on tissue perfusion have not been investigated. METHODS Ventricular fibrillation was induced in eight anesthetized, intubated animals. ACD-CPR and standard CPR were each performed twice in alternating order. All interventions were preceded by 1 min of ventricular fibrillation, in which no CPR was performed, and consisted of 6 min of CPR with either technique during which tissue perfusion was measured. Compressions were performed at 80/min with a 50 percent duty cycle and 175 to 200 N downward force applied to the chest wall for both techniques. Epinephrine was administered at the beginning of each 6-min CPR interval. Hemodynamic monitoring of aortic and right atrial pressure was performed continuously and myocardial, cerebral, and renal blood flows were measured using the radiolabeled microsphere technique at baseline and during all interventions. RESULTS Baseline organ perfusion and hemodynamics were similar for all dogs. Baseline left ventricular, brain, and renal blood flows were 62.0 +/- 5.5, 14.1 +/- 2.1, and 476.3 +/- 55.5 ml/min/100 g, respectively (mean +/- SEM). Compared with standard CPR, ACD-CPR resulted in higher global left ventricular (22.5 +/- 6.2 vs 14.1 +/- 4.0 ml/min/100 g, p < 0.01), cerebral (12.0 +/- 2.4 vs 8.5 +/- 2.3 ml/min/100 g, p < 0.01), and renal cortical (27.8 +/- 5.0 vs 17.5 +/- 5.0 ml/min/100 g, p < 0.05) blood flows. Regional flows to the epicardium, endocardium, and midmyocardium as well as to the frontal, parietal, and occipital lobes of the brain were all significantly improved by ACD-CPR. Aortic systolic (61.7 +/- 4.1 vs 49.5 +/- 3.1 mm Hg, p < 0.01), aortic mean (31.6 +/- 2.8 vs 27.2 +/- 2.2 mm Hg, p = 0.001), and myocardial perfusion pressure (12.9 +/- 3.4 vs 10.4 +/- 3.4 mm Hg, ACD-CPR vs standard CPR, p < 0.01) were all higher during ACD-CPR than during standard CPR. CONCLUSIONS We conclude that ACD-CPR improves tissue perfusion and systemic hemodynamics compared with standard CPR.
منابع مشابه
Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.
Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...
متن کاملEffect of regulating airway pressure on intrathoracic pressure and vital organ perfusion pressure during cardiopulmonary resuscitation: a non-randomized interventional cross-over study
BACKGROUND The objective of this investigation was to evaluate changes in intrathoracic pressure (Ppl), airway pressure (Paw) and vital organ perfusion pressures during standard and intrathoracic pressure regulation (IPR)-assisted cardiopulmonary resuscitation (CPR). METHODS Multiple CPR interventions were assessed, including newer ones based upon IPR, a therapy that enhances negative intrath...
متن کاملEvaluation of standard and active compression-decompression CPR in an acute human model of ventricular fibrillation.
BACKGROUND The mechanisms that underlie cardiopulmonary resuscitation (CPR) in humans remain controversial and difficult to study. This report describes a new human model to evaluate CPR during the first 1 to 2 minutes after the onset of ventricular fibrillation (VF). With this model, standard CPR was compared with active compression-decompression (ACD) CPR, a method that uses a handheld suctio...
متن کاملThe effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve.
UNLABELLED The use of an inspiratory impedance threshold valve (ITV) during active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) improves perfusion pressures, and vital organ blood flow. We evaluated the effects of positive end-expiratory pressure (PEEP) on gas exchange, and coronary perfusion pressure gradients during ACD + ITV CPR in a porcine cardiac arrest model. All a...
متن کاملOptimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve.
OBJECTIVES This study was designed to assess whether intermittent impedance of inspiratory gas exchange improves the efficiency of standard cardiopulmonary resuscitation (CPR). BACKGROUND Standard CPR relies on the natural elastic recoil of the chest to transiently decrease intrathoracic pressures and thereby promote venous blood return to the heart. To further enhance the negative intrathora...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 106 4 شماره
صفحات -
تاریخ انتشار 1994