A 10μA on-chip electrochemical impedance spectroscopy system for wearables/implantables
نویسندگان
چکیده
This work proposes a new time-domain integration method to realize Electrochemical Impedance Spectroscopy (EIS). Unlike traditional EIS systems which use a quadrature sinusoid stimulus, we propose a low-frequency, lowamplitude sinusoid stimulus, which is realized through a sinusoid DAC without the need for analog filter. The error caused by harmonic generation can be suppressed through integration in detection. The response current is sensed by a switched capacitor integrator with control synchronized with sinusoid DAC. The integration output is sampled and digitized by an 8-bit SAR ADC. The (1×1.1) prototype is fabricated in a 130nm CMOS process. It consumes 10μA from a 1.2V supply. Keywords— Electrochemical Impedance Spectroscopy, sinusoid DAC, time-domain integration
منابع مشابه
On-chip latex agglutination immunoassay readout by electrochemical impedance spectroscopy.
We describe a new class of impedance-based lab-on-chip immunosensors in which the immunoagglutination of latex is monitored by electrochemical impedance spectroscopy (EIS). Antibody-coated latex microspheres agglutinated in the presence of target antigens are precipitated from solution between interdigitated microsized electrodes on a chip. Impedance spectra are reproducibly measured in the 0.1...
متن کاملElectrochemical Impedance Spectroscopy for Investigation of Different Losses in 4-cells Short Stack with Integrated Humidifier and Water Separator
Electrochemical impedance spectroscopy (EIS) is a suitable and powerful diagnostic testing method for fuel cells (FCs) since it is non-destructive and provides useful information about FC performance and its components. In this study, for the first time, a 500W cascade type 4 cells stack with integrated humidifier, water separator and internal manifolds was designed, fabricated and tested. The ...
متن کاملUsing electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode
In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...
متن کاملApplication of Electrochemical Noise to Investigate Corrosion Inhibition Properties of Some Azole Compounds on Aluminum in 0.25 M HCl
The corrosion inhibition properties of the benzothiazole BTH and benzotriazole BT inhibitors on the aluminum in 0.25 M HCl solution were studied. Electrochemical impedance spectroscopy EIS, electrochemical noise EN and potentiodynamic polarization techniques were used to investigate the inhibition properties of the inhibitors. Scanning electron microscope SEM was also utilized in order to inves...
متن کاملWideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy
This paper presents a multi-channel dual-mode CMOS analogue front-end (AFE) for electrochemical and bioimpedance analysis. Current-mode and voltage-mode readouts, integrated on the same chip, can provide an adaptable platform to correlate single-cell biosensor studies with large-scale tissue or organ analysis for real-time cancer detection, imaging and characterization. The chip, implemented in...
متن کامل