Ultrasound-induced lung hemorrhage: role of acoustic boundary conditions at the pleural surface.
نویسندگان
چکیده
In a previous study [J. Acoust. Soc. Am. 108, 1290 (2000)] the acoustic impedance difference between intercostal tissue and lung was evaluated as a possible explanation for the enhanced lung damage with increased hydrostatic pressure, but the hydrostatic-pressure-dependent impedance difference alone could not explain the enhanced occurrence of hemorrhage. In that study, it was hypothesized that the animal's breathing pattern might be altered as a function of hydrostatic pressure, which in turn might affect the volume of air inspired and expired. The acoustic impedance difference between intercostal tissue and lung would be affected with altered lung inflation, thus altering the acoustic boundary conditions. In this study, 12 rats were exposed to 3 volumes of lung inflation (inflated: approximately tidal volume; half-deflated: half-tidal volume; deflated: lung volume at functional residual capacity), 6 rats at 8.6-MPa in situ peak rarefactional pressure (MI of 3.1) and 6 rats at 16-MPa in situ peak rarefactional pressure (MI of 5.8). Respiration was chemically inhibited and a ventilator was used to control lung volume and respiratory frequency. Superthreshold ultrasound exposures of the lungs were used (3.1-MHz, 1000-Hz PRF, 1.3-micros pulse duration, 10-s exposure duration) to produce lesions. Deflated lungs were more easily damaged than half-deflated lungs, and half-deflated lungs were more easily damaged than inflated lungs. In fact, there were no lesions observed in inflated lungs in any of the rats. The acoustic impedance difference between intercostal tissue and lung is much less for the deflated lung condition, suggesting that the extent of lung damage is related to the amount of acoustic energy that is propagated across the pleural surface boundary.
منابع مشابه
Estimation of the acoustic impedance of lung versus level of inflation for different species and ages of animals.
In a previous study, it was hypothesized that ultrasound-induced lung damage was related to the transfer of ultrasonic energy into the lungs (W. D. O'Brien et al. 2002, "Ultrasound-induced lung hemorrhage: Role of acoustic boundary conditions at the pleural surface," J. Acoust. Soc. Am. 111, 1102-1109). From this study a technique was developed to: 1) estimate the impedance (Mrayl) of fresh, ex...
متن کاملThreshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.
The objective of this study was to assess the threshold and superthreshold behavior of ultrasound (US)-induced lung hemorrhage in adult rabbits to gain greater understanding about species dependency. A total of 99 76 +/- 7.6-d-old 2.4 +/- 0.14-kg New Zealand White rabbits were used. Exposure conditions were 5.6-MHz, 10-s exposure duration, 1-kHz PRF and 1.1-micros pulse duration. The in situ (a...
متن کاملThreshold estimation and superthreshold behavior of ultrasound-induced lung hemorrhage in rats: role of age dependency.
Age-dependent threshold and superthreshold behaviors of ultrasound-induced lung hemorrhage were investigated with one hundred ten 12.6 +/- 0.8-d-old rats, one hundred ten 22.9 +/- 0.8-d-old rats, and one hundred 57.7 +/- 3.9-d-old rats. Exposure conditions were: 2.8 MHz, 10-s exposure duration, 1-kHz pulse repetition frequency and 1.3-mus pulse duration. The in situ (at the pleural surface) pea...
متن کاملSuperthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and exposure duration revisited.
OBJECTIVE The purpose of this study was to augment and reevaluate the ultrasound-induced lung hemorrhage findings of a previous 5 x 3 factorial design study (Ultrasound Med Biol 2001; 27:267-277) that evaluated the role of pulse repetition frequency (PRF: 25, 50, 100, 250, and 500 Hz) and exposure duration (ED; 5, 10, and 20 s) on ultrasound-induced lung hemorrhage at an in situ (at the pleural...
متن کاملComparison of mouse and rabbit lung damage exposure to 30 kHz ultrasound.
Twenty-four mice and sixteen rabbits were evaluated at one exposure duration (10 min) and at three exposure acoustic pressure levels (0, 100 and 145 kPa) at an ultrasonic frequency of 30 kHz, continuous wave for the purpose of testing whether there was a species difference in the degree of sensitivity to ultrasound-induced lung damage. This study was undertaken because it was hypothesized that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 111 2 شماره
صفحات -
تاریخ انتشار 2002