23-gauge vitrectomy with intraocular foreign body removal via the limbus: An alternative approach for select cases

نویسندگان

  • Ramandeep Singh
  • Swapnil Bhalekar
  • Mangat R. Dogra
  • Amod Gupta
چکیده

PURPOSE To study the outcome of removal of retained intraocular foreign bodies (RIOFBs) via limbus using 23-gauge transconjunctival sutureless vitrectomy (TSV). MATERIALS AND METHODS In this prospective, non-comparative interventional case series, fourteen eyes of 14 patients fulfilling the inclusion criteria were enrolled. They underwent 23-gauge TSV for management of posterior segment RIOFB and reviewed at 1 day, 7 days, 6 weeks, 3, 6 and 12 months. Eyes with penetrating eye injury involving cornea or limbus (corneal injury not so severe to hinder vitrectomy), cataract associated with anterior and/or posterior capsular tear requiring cataract surgery and posterior segment RIOFB with minimal posterior segment involvement were included. Main outcome measures include success in removal of RIOFB without enlarging sclerotomy, ability to preserve capsular support, improvement in visual acuity and complications, if any. RESULTS All eyes underwent the successful RIOFB removal through limbal port without enlarging scleral ports. None of the eyes required suturing of the sclera, cornea or conjunctiva. Anterior capsular rim could be preserved in all eyes except one. Postoperatively follow up ranged from one year in 8, 6 months in 4 and 3 months in 2 eyes. The mean logMAR visual acuity at 3, 6, and 12 months showed significant improvement. There were no intraoperative complications. Postoperative complications include microscopic hyphema and loose blood in vitreous cavity in one eye. CONCLUSION The advantages of 23-gauge TSV for removal of RIOFB may be passed on to select cases. RIOFB removal through limbal route obviated the need for scleral port enlargement and preserved capsular support for early visual rehabilitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

25-Gauge Vitrectomy in Open Eye Injury with Retained Foreign Body

Purpose. Ocular trauma with retained foreign body is an important cause of visual impairment in working-age population. Clinical status impacts on the timing and planning of surgery. In the last year small gauge vitrectomy has become safer and more efficient, extending the range of pathologies successfully treated. Aims. To evaluate the safety and outcomes in patients with open eye injury with ...

متن کامل

23 Gauge pars plana vitrectomy for the removal of retained intraocular foreign bodies

BACKGROUND To evaluate the morpho-functional outcomes and safety of transconjuctival 23-gauge pars plana vitrectomy(PPV) for removal of intraocular foreign bodies (IOFBs). METHODS A retrospective study of 36 consecutive cases (mean age; 34,2 ± 10,9 years (between 15 and 60), 27 M,9 F) of 23-G PPV for the removal of IOFBs during the period of April 2009 and December 2011 and followed 9,4 ± 6,4...

متن کامل

Intraoperative Macula Protection by Perfluorocarbon Liquid for the Metallic Intraocular Foreign Body Removal during 23-Gauge Vitrectomy

Purpose. To evaluate visual and safety outcomes of 23-gauge (G) pars plana vitrectomy (PPV) with application of perfluorocarbon liquid (PFCL) for intraoperative protection of the macula during intraocular foreign body (IOFB) removal. Methods. Retrospective study of 42 patients who underwent 23 G PPV for IOFB removal from posterior segment with intraoperative PFCL application for the macula shie...

متن کامل

Successful Removal of Large Intraocular Foreign Body by 25-Gauge Microincision Vitrectomy Surgery

We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS). Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. T...

متن کامل

Intraoperative endoscopic observation of sclerotomy site after cannula removal for 23-gauge vitrectomy

BACKGROUND The purpose of this study was to determine the incidence of vitreous incarceration in sclerotomy after cannula removal during 23-gauge vitrectomy. METHODS Thirty-seven eyes underwent 23-gauge sutureless vitrectomy. Oblique sclerotomies were made parallel to the limbus and tangentially to the sclera. Once past the trocar sleeve, the angle was changed to 90 degrees perpendicular to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 62  شماره 

صفحات  -

تاریخ انتشار 2014