Effect of the magnetic field on positron range using GATE for PET-MR
نویسندگان
چکیده
Division of Medical Physics, University of Leeds, UK Positron range is an important spatial resolution limiting factor in PET. When imaging inside a magnetic field the positron range is non-uniformly affected. A decrease of the positron range is expected in the directions perpendicular to the direction of the magnetic field, whereas no variation is expected in the direction of the magnetic field. Monte Carlo simulations were performed to validate these expectations. GATE simulation package [1] (version 5.0.0) was used to calculate the annihilation distribution of positrons in water, lung and rib bone. A point source placed in the centre of a spherical phantom was simulated. Six different positron emitters were used: C, 13 N, O, F, Ga, Rb. The simulations were performed without and with static magnetic field set in the axial direction for various field strengths. In total 105 annihilation events were simulated per configuration and the annihilation coordinates were obtained from the Geant4 output and analysed with Matlab. Previous investigations indicated an increase of the positron range along the axis of the magnetic field [2,3]. As an attempt to confirm the previous findings, the effect of the magnetic field on the positron emission range was investigated. GATE simulations of the positron annihilation process indicated a general reduction of the mean positron range inside the phantom volume, specifically for the high energy emitters Rb and Ga. The evaluation of the positron annihilation distance across the directions perpendicular to the magnetic field showed a reduction of the mean positron range, as theoretically expected [4,5]. These results are compared and found in accordance with the theoretical expectations [2,3]. Contrary to previously published results [2,3], no increase in the positron range along the direction of the magnetic field is detected. The results of this study can be used to improve positron range correction algorithms for simultaneous PET-MR acquisition.
منابع مشابه
Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملPET iterative reconstruction incorporating an efficient positron range correction method.
Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image r...
متن کاملThe importance of attenuation correction for coincidence positron tomography on hybrid PET/SPECT gamma camera system
Abstract is NOT available
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملPositron tomography of breast cancer in a community hospital: A case study of advanced disease using a coincidence gamma camera
Until recently PET scanning has been available only at major universities or teaching hospitals possessing the necessary resources and expertise to operate a research PET facility. Most dedicated PET centers cost several millions of dollars, and include a cyclotron, a radiochemistry laboratory to synthesize PET radiopharmaceuticals, a multicrystal dedicated PET camera, advanced computer f...