Accelerating degradation rate of pure iron by zinc ion implantation
نویسندگان
چکیده
Pure iron has been considered as a promising candidate for biodegradable implant applications. However, a faster degradation rate of pure iron is needed to meet the clinical requirement. In this work, metal vapor vacuum arc technology was adopted to implant zinc ions into the surface of pure iron. Results showed that the implantation depth of zinc ions was about 60 nm. The degradation rate of pure iron was found to be accelerated after zinc ion implantation. The cytotoxicity tests revealed that the implanted zinc ions brought a slight increase on cytotoxicity of the tested cells. In terms of hemocompatibility, the hemolysis of zinc ion implanted pure iron was lower than 2%. However, zinc ions might induce more adhered and activated platelets on the surface of pure iron. Overall, zinc ion implantation can be a feasible way to accelerate the degradation rate of pure iron for biodegradable applications.
منابع مشابه
The Suitability of Zn–1.3%Fe Alloy as a Biodegradable Implant Material
Efforts to develop metallic zinc for biodegradable implants have significantly advanced following an earlier focus on magnesium (Mg) and iron (Fe). Mg and Fe base alloys experience an accelerated corrosion rate and harmful corrosion products, respectively. The corrosion rate of pure Zn, however, may need to be modified from its reported ~20 μm/year penetration rate, depending upon the intended ...
متن کاملPhoto-degradation of Methylene Orange by zinc-sulfide nanoparticles synthesized via hydrothermal method
Background and Objective: In the present research, the synthesis and characterization of ZnS nanoparticles in zinc blend crystallite phase via hydrothermal method were reported. Advanced oxidation processes using nanophotocatalysts are one of the most efficient methods for removing the dyes with complex organic compounds from textile and industrial wastewaters. The photocatalytic performance of...
متن کاملControlling the degradation kinetics of porous iron by poly(lactic-co-glycolic acid) infiltration for use as temporary medical implants
Iron and its alloy have been proposed as biodegradable metals for temporary medical implants. However, the formation of iron oxide and iron phosphate on their surface slows down their degradation kinetics in both in vitro and in vivo scenarios. This work presents new approach to tailor degradation behavior of iron by incorporating biodegradable polymers into the metal. Porous pure iron (PPI) wa...
متن کاملIs aging recorded in blood Cu and Zn isotope compositions?
Recent isotopic observations of animal samples indicate body accumulation of heavy zinc and light copper throughout life. This hypothesis has never been tested for humans, but the existence of a relationship between blood isotopic composition and age could be promising for age assessment methodologies. Dietary habits can also influence the blood zinc isotope composition, being an additional sou...
متن کاملTheoretical Treatment of Krypton Ion Beam Bombardement in Zinc Target
The manuscript reports a study of Kr ion implantation in a Zn target in the 10-50 keV energy range at different source parameters, which combines experimental data and simulation with the SRIM package. The implanted thickness for the 45 keV was found to be 10 μm. The ion penetration depths for different films at different energies (10-50 keV) were calculated using SRIM computer program and foun...