A Diagnostic System For Photolithography Equipment

نویسندگان

  • Sovarong Leang
  • Costas Spanos
چکیده

This paper presents a general diagnostic system that can be applied to semiconductor equipment to assist the operator in finding the causes of decreased machine performance. Based on conventional probability theory, the diagnostic system incorporates both shallow and deep level information. From the observed evidence, and from the conditional probabilities of faults initially supplied by machine experts (and subsequently updated by the system), the fault probabilities and their bounds are calculated, given a specified confidence level. The rate of convergence of the fault probabilities has been derived in detail in the paper, and the procedure for combining the estimates of conditional probabilities given by the machine experts has also been described in detail. We have implemented a software version of the diagnostic system, and tested it on real photolithography equipment malfunctions and performance drifts. Initial experimental results are encouraging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

Fabrication of conical microneedles array using photolithography

Background and Aim: Microneedle technology has led to huge changes in the field of drug delivery medicine. Using microneedles, the drug can be injected locally, painlessly, and in very low and controlled doses with high precision. Local drug delivery through the skin with microneedles has many advantages over other methods of drug delivery. In this method, the drug does not enter the gastrointe...

متن کامل

The Rate of Occupational Exposure to Patients’ Specimen among Personnel of Medical Diagnostic Laboratories in Birjand City

Abstract Background and Objective: Having knowledge about potential risks and the usage of safety equipment in laboratories can decrease the risk of occupational exposure. The aim of this study was to evaluate the predisposing factors for occupational exposure and to assess the usage of safety equipment among personnel of medical diagnostic laboratories in Birjand. Material and Methods: In ...

متن کامل

A Fuzzy Scheduling System for Dedicated Machine Constraint

In this paper, we propose the Fuzzy Scheduling System (FSS) to deal with the dedicated machine constraint. The constraint of having a dedicated machine for photolithography process is the new issue introduced in photolithography machinery due to natural bias. If we randomly schedule the wafer lots to arbitrary photolithography machines at the first photolithography stage, then the load of all p...

متن کامل

Correlation of Wafer Backside Defects to Photolithography Hot Spots Using Advanced Macro Inspection

Defects on the backside of a wafer during processing can come from many sources. Particles and scratches on the backsides of wafers can be caused by wafer handling equipment such as robots and chucks, as well as by CMP processes. In addition, cross-contamination of wafers and handling equipment can occur when wafers move from tool to tool, through the production line. When wafers are exposed, b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998