Attenuation Effects of MR Headphones During Brain PET/MR Studies.
نویسندگان
چکیده
UNLABELLED PET/MR offers potential advantages over PET/CT that are currently under investigation. One of the challenges of PET/MR is attenuation correction, as there is no simple correlation between MR signal intensity and the attenuation of 511-keV photons detected in PET. Currently, dedicated MR sequences are used to segment voxels into categories that are then assigned a predetermined attenuation coefficient. MR hardware such as the imaging table, coils, and headphones are also sources of attenuation. The purpose of this study was to evaluate the effect of MR-compatible headphones on average activity concentration measured with PET/MR. We also present a practical approach to correct for the attenuation effect of headphones using a CT-derived attenuation map. METHODS Phantom studies were performed using a 3-L cylindric phantom containing 55 MBq of (18)F-FDG and water. Images were acquired on a PET/MR device in 2 settings-one with the PET/MR headphones on and one with the headphones off. Phantom images were analyzed to compare activity concentration with headphones on and off. A high-resolution CT and (57)Co transmission scan was obtained to construct a PET attenuation map of the headphones. The resulting attenuation map was registered to the phantom data to evaluate the ability to correct for headphone attenuation. One human subject was scanned to evaluate the clinical impact of headphone attenuation and the accuracy of the proposed correction. RESULTS Activity concentrations measured in the phantom were reduced by as much as 13.2% with headphones on compared with headphones off. Using the modified attenuation maps that account for attenuation from the headphones resulted in a decrease in the headphone attenuation effect from a maximum of 13.2% to 1.9%. Comparable attenuation effects were observed in the human brain and were similarly reduced with correction using the modified attenuation maps. CONCLUSION MR-safe headphones were a source of attenuation on our PET/MR phantom and human studies. Attenuation effects of headphones should be considered and can be corrected during quantitative brain PET/MR studies.
منابع مشابه
Impact of MR-safe headphones on PET attenuation in combined PET/MRI scans
BACKGROUND MR headphones are attenuation sources affecting PET quantification in hybrid PET/MRI. Despite potentially better patient communication, usage in PET/MRI scans is not approved by the vendor. This study aims to determine the impact of headphones on PET by means of phantom and patient scans. Additionally, the perceived benefit of using headphones was evaluated. FINDINGS A cylinder pha...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملMLAA-based attenuation correction of flexible hardware components in hybrid PET/MR imaging
BACKGROUND Accurate PET quantification demands attenuation correction (AC) for both patient and hardware attenuation of the 511 keV annihilation photons. In hybrid PET/MR imaging, AC for stationary hardware components such as patient table and MR head coil is straightforward, employing CT-derived attenuation templates. AC for flexible hardware components such as MR-safe headphones and MR radiof...
متن کاملEvaluation of a clinical PET/MR system
Hybrid imaging devices combining Positron-Emission-Tomography (PET) with Magnetic-Resonance-Imaging (MRI) have been shown to possess a great potential for small animal studies. Recently PET/MR systems have also been built for human applications. Here we present an evaluation of the first hybrid PET/MR device, which has the capabilities to perform simultaneous PET/MR acquisitions of the human br...
متن کاملSegmentation-based MR attenuation correction including bones also affects quantitation in brain studies: an initial result of 18F-FP-CIT PET/MR for patients with parkinsonism.
UNLABELLED Attenuation correction (AC) with an ultrashort echo time (UTE) sequence has recently been used in combination with segmentation for cortical bone identification for brain PET/MR studies. The purpose of this study was to evaluate the quantification of (18)F-fluoropropyl-carbomethoxyiodophenylnortropane ((18)F-FP-CIT) binding in brain PET/MR, particularly focusing on effects of UTE-bas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 42 2 شماره
صفحات -
تاریخ انتشار 2014