Operator training requirements and diagnostic accuracy of Fibroscan in routine clinical practice

نویسندگان

  • M J Armstrong
  • C Corbett
  • J Hodson
  • N Marwah
  • R Parker
  • D D Houlihan
  • I A Rowe
  • J M Hazlehurst
  • R Brown
  • S G Hübscher
  • D Mutimer
چکیده

BACKGROUND Fibroscan is a quick, non-invasive technique used to measure liver stiffness (kPa), which correlates with fibrosis. To achieve a valid liver stiffness evaluation (LSE) the operator must obtain all the following three criteria: (1) ≥10 successful liver stiffness measurements; (2) IQR/median ratio <0.30 and (3) ≥60% measurement success rate. OBJECTIVES To assess the operator training requirements and the importance of adhering to the LSE validity criteria in routine clinical practice. METHODS We retrospectively analysed the LSE validity rates of 2311 Fibroscans performed (1 August 2008 to 31 July 2011) in our tertiary liver outpatients department at the University Hospital Birmingham, UK. The diagnostic accuracy of Fibroscan was assessed in 153 patients, by comparing LSE (valid and invalid) with the modified Ishak fibrosis stage on liver biopsy. RESULTS Learning curve analysis highlighted that the greatest improvement in validity of LSE rates occurs in the operator's first 10 Fibroscans, reaching 64.7% validity by the 50th Fibroscan. The correlation between LSE and the fibrosis stage on liver biopsy was superior in patients with a valid LSE (n=97) compared with those with an invalid LSE (n=56) (rs 0.577 vs 0.259; p=0.022). Area under receiving operating characteristics for significant fibrosis was greater when LSE was valid (0.83 vs 0.66; p=0.048). Using an LSE cut-off of 8 kPa, the negative predictive value of valid LSE was superior to invalid LSE for the detection of significant (84% vs 71%) and advanced fibrosis (100% vs 93%). CONCLUSIONS Fibroscan requires minimal operator training (≥10 observed on patients), and when a valid LSE is obtained, it is an accurate tool for excluding advanced liver fibrosis. To ensure the diagnostic accuracy of Fibroscan it is essential that the recommended LSE validity criteria are adhered to in routine clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ARFI, FibroScan, ELF, and their combinations in the assessment of liver fibrosis: a prospective study.

BACKGROUND & AIMS Our aim was to evaluate a serologic marker (ELF) and two ultrasound-based methods (FibroScan and ARFI), as well as their combinations, in the assessment of liver fibrosis. METHODS One-hundred and forty-six patients (87 liver transplant recipients, 59 non-transplant patients) who underwent liver biopsy were prospectively included. We evaluated the diagnostic accuracy of Fibro...

متن کامل

دیدگاه عاملین زایمان در مورد اپیزیاتومی روتین: یک مطالعه کیفی

Background and purpose: Many studies have determined desirable outcomes of elective episiotomy. However, the clinical practice is not based on results in many hospitals. For this reason, the present study assessed the view of practitioners regarding routine episiotomy. Materials and methods: This qualitative study was done by content analysis. A through semi-structured interview was done w...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

Acoustic radiation force impulse elastography, FibroScan®, Forns’ index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods

The aim of the present study was to investigate the combination of certain serological markers (Forns' index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty‑one patients who had been diagn...

متن کامل

Academic training and clinical placement problems to achieve nursing competency

Introduction: High quality of care is one of the requirementsof nursing which depends on the nursing competency. In thisconnection, the aim of this research was to determine theproblems related to the academic training (nursing’ educationalprogram) and clinical practice to achieve competency from theviewpoint of nurses, faculty members, and nursing students.Methods: The study was an analytical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2013