Comparison of capillary and arterial blood gas measurements in neonates.

نویسندگان

  • B I McLain
  • J Evans
  • P R Dear
چکیده

One hundred and fifty eight paired arterial and capillary blood samples were obtained from 41 sick preterm infants in their first week of life and the pH, and PCO2, and PO2 concentrations were measured. Half of the capillary samples were obtained from unwarmed heels and half from heels warmed to 40 degrees C. A potentially significant discrepancy (arbitrarily defined as 0.05 units for pH. 1 kPa for PCO2, and 3 kPa for PO2) was found in 19 (24%) of cases for pH, in 9 (11%) for PCO2 and in 21 (26%) for PO2. Warming the heel produced no significant improvement in results. We conclude that capillary blood provides satisfactory measurements of pH and PCO2 for all but the most critical purposes, but that the usefulness of capillary PO2 estimations is limited to the exclusion of hypoxia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

متن کامل

Umbilical Cord Arterial Blood Gas and Apgar Score: Who Is at Higher Risk?

Background: Fetal asphyxia and the consequent neurological damages could be avoided if the risk factors are controlled at earlier stages. Umbilical cord arterial blood gas (UCABG) seems to be related to the Apgar scores, as well as the neonatal morbidity and mortality rates. Therefore, we designed this study to assess the correlation between the Apgar score and UCABG i...

متن کامل

Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit.

AIMS To investigate the correlation of pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), base excess (BE), and bicarbonate (HCO3) between arterial (ABG), venous (VBG), and capillary (CBG) blood gases. METHODS Patients admitted to the paediatric intensive care unit (PICU) in Cukurova University between August 2000 and February 2002 were enrolled. RESULTS A tota...

متن کامل

Evaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates

Abstract Background Anemia is one of the most common abnormalities in pediatric medicine. Considerable differences are seen in the peripheral blood indices of infants in developing countries. The aim of this study was to determine and compared blood hemoglobin concentration in three sites of sampling in neonate. Materials and Methods 1600 term and preterm new infant in three sites of sampli...

متن کامل

Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.

OBJECTIVE Arterial oxygen saturation (Sao(2)) and arterial carbon dioxide partial pressure (Paco(2)) are 2 of the most important respiratory parameters in the treatment of critically ill neonates. Noninvasive monitoring of these parameters is desirable for continuous estimating of the respiratory status and reducing blood loss because of repeated blood gas analyses. Transcutaneous measurement o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 63 7 Spec No  شماره 

صفحات  -

تاریخ انتشار 1988