Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes
نویسندگان
چکیده
BACKGROUND Our objective was to determine the cost-effectiveness of Continuous Glucose Monitoring (CGM) technology with intensive insulin therapy compared to self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes in the United States. METHODS A Markov cohort analysis was used to model the long-term disease progression of 12 different diabetes disease states, using a cycle length of 1 year with a 33-year time horizon. The analysis uses a societal perspective to model a population with a 20-year history of diabetes with mean age of 40. Costs are expressed in $US 2007, effectiveness in quality-adjusted life years (QALYs). Parameter estimates and their ranges were derived from the literature. Utility estimates were drawn from the EQ-5D catalogue. Probabilities were derived from the Diabetes Control and Complications Trial (DCCT), the United Kingdom Prospective Diabetes Study (UKPDS), and the Wisconsin Epidemiologic Study of Diabetic Retinopathy. Costs and QALYs were discounted at 3% per year. Univariate and Multivariate probabilistic sensitivity analyses were conducted using 10,000 Monte Carlo simulations. RESULTS Compared to SMBG, use of CGM with intensive insulin treatment resulted in an expected improvement in effectiveness of 0.52 QALYs, and an expected increase in cost of $23,552, resulting in an ICER of approximately $45,033/QALY. For a willingness-to-pay (WTP) of $100,000/QALY, CGM with intensive insulin therapy was cost-effective in 70% of the Monte Carlo simulations. CONCLUSIONS CGM with intensive insulin therapy appears to be cost-effective relative to SMBG and other societal health interventions.
منابع مشابه
Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.
Continuous glucose monitoring for type 1 diabetes mellitus will go forward for refinement as a systematic review. The scope of this topic, including populations, interventions, comparators, and outcomes, will be further developed in the refinement phase. When key questions have been drafted, they will be posted on the AHRQ Web site and open for public comment. To sign up for notification wh...
متن کاملCost effectiveness of self monitoring of blood glucose in patients with non-insulin treated type 2 diabetes: economic evaluation of data from the DiGEM trial.
OBJECTIVE To assess the cost effectiveness of self monitoring of blood glucose alone or with additional training in incorporating the results into self care, in addition to standardised usual care for patients with non-insulin treated type 2 diabetes. DESIGN Incremental cost utility analysis from a healthcare perspective. Data on resource use from the randomised controlled diabetes glycaemic ...
متن کاملEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment Evidence from the Juvenile Diabetes Research Foundation Continuous Glucose Monitoring (JDRF-CGM) trial JUVENILE DIABETES RESEARCH FOUNDATION CONTINUOUS GLUCOSE MONITORING
RESEARCH DESIGN AND METHODS — After completion of a 6-month randomized controlled trial (RCT) evaluating CGM in children, adolescents, and adults with type 1 diabetes, CGM was initiated in the trial’s control group with less intensive training and follow-up than was included in the RCT. Subjects had an outpatient training session, two follow-up phone calls, and outpatient visits at 1, 4, 13, an...
متن کاملEmerging Technologies for the Management of Type 1 Diabetes in Pregnancy
PURPOSE OF REVIEW The purpose of the study is to discuss emerging technologies available in the management of type 1 diabetes in pregnancy. RECENT FINDINGS The latest evidence suggests that continuous glucose monitoring (CGM) should be offered to all women on intensive insulin therapy in early pregnancy. Studies have additionally demonstrated the ability of CGM to help gain insight into speci...
متن کاملCombined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.
OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...
متن کامل