Evaluation of different set-up error corrections on dose–volume metrics in prostate IMRT using CBCT images

نویسندگان

  • Yoshinori Hirose
  • Mitsuhiro Nakamura
  • Tsuneyuki Tomita
  • Kenji Kitsuda
  • Takuya Notogawa
  • Katsuhito Miki
  • Kiyonao Nakamura
  • Takashi Ishigaki
چکیده

We investigated the effect of different set-up error corrections on dose-volume metrics in intensity-modulated radiotherapy (IMRT) for prostate cancer under different planning target volume (PTV) margin settings using cone-beam computed tomography (CBCT) images. A total of 30 consecutive patients who underwent IMRT for prostate cancer were retrospectively analysed, and 7-14 CBCT datasets were acquired per patient. Interfractional variations in dose-volume metrics were evaluated under six different set-up error corrections, including tattoo, bony anatomy, and four different target matching groups. Set-up errors were incorporated into planning the isocenter position, and dose distributions were recalculated on CBCT images. These processes were repeated under two different PTV margin settings. In the on-line bony anatomy matching groups, systematic error (∑) was 0.3 mm, 1.4 mm, and 0.3 mm in the left-right, anterior-posterior (AP), and superior-inferior directions, respectively. ∑ in three successive off-line target matchings was finally comparable with that in the on-line bony anatomy matching in the AP direction. Although doses to the rectum and bladder wall were reduced for a small PTV margin, averaged reductions in the volume receiving 100% of the prescription dose from planning were within 2.5% under all PTV margin settings for all correction groups, with the exception of the tattoo set-up error correction only (≥ 5.0%). Analysis of variance showed no significant difference between on-line bony anatomy matching and target matching. While variations between the planned and delivered doses were smallest when target matching was applied, the use of bony anatomy matching still ensured the planned doses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters

Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

Determination of optimal PTV margin for patients receiving CBCT‐guided prostate IMRT: comparative analysis based on CBCT dose calculation with four different margins

Variations in daily setup and rectum/bladder filling lead to uncertainties in the delivery of prostate IMRT. The purpose of this study is to determine the optimal PTV margin for CBCT-guided prostate IMRT based on daily CBCT dose calculations using four different margins. Five patients diagnosed with low-risk prostate cancer were treated with prostate IMRT to 70 Gy in 28 fractions using daily CB...

متن کامل

The effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer

Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014