Detection of Shigella in Milk and Clinical Samples by Magnetic Immunocaptured-Loop-Mediated Isothermal Amplification Assay
نویسندگان
چکیده
Shigella is an important human food-borne zoonosis bacterial pathogen, and can cause clinically severe diarrhea. There is an urgent need to develop a specific, sensitive, and rapid methodology for detection of this pathogen. In this study, loop-mediated isothermal amplification (LAMP) combined with magnetic immunocapture assay (IC-LAMP) was first developed for the detection of Shigella in pure culture, artificial milk, and clinical stool samples. This method exhibited a detection limit of 8.7 CFU/mL. Compared with polymerase chain reaction, IC-LAMP is sensitive, specific, and reliable for monitoring Shigella. Additionally, IC-LAMP is more convenient, efficient, and rapid than ordinary LAMP, as it is more efficiently enriches pathogen cells without extraction of genomic DNA. Under isothermal conditions, the amplification curves and the green fluorescence were detected within 30 min in the presence of genomic DNA template. The overall analysis time was approximately 1 h, including the enrichment and lysis of the bacterial cells, a significantly short detection time. Therefore, the IC-LAMP methodology described here is potentially useful for the efficient detection of Shigella in various samples.
منابع مشابه
A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2
Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...
متن کاملLoop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملRapid and Sensitive Detection of Shigella spp. and Salmonella spp. by Multiple Endonuclease Restriction Real-Time Loop-Mediated Isothermal Amplification Technique
Shigella and Salmonella are frequently isolated from various food samples and can cause human gastroenteritis. Here, a novel multiple endonuclease restriction real-time loop-mediated isothermal amplification technology (MERT-LAMP) were successfully established and validated for simultaneous detection of Shigella strains and Salmonella strains in only a single reaction. Two sets of MERT-LAMP pri...
متن کاملتشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification
Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...
متن کاملLAMP assay for rapid diagnosis of cow DNA in goat milk and meat samples
Animal species detection is one of the crucial steps for consumer’s food analysis. In the present study we developed an in-house built loop-mediated isothermal amplification (LAMP) assay for rapid detection of adulterated cow DNA in goat milk/meat samples. The cow milk/tissue DNA in goat milk/meat samples were identified in the developed LAMP assay by either naked eye visualizing with SYBR Gree...
متن کامل