Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling.
نویسندگان
چکیده
BACKGROUND Continuous-flow left ventricular assist devices (LVAD) are increasingly used for patients with end-stage heart failure (HF). We analyzed the effects of ventricular decompression by continuous-flow versus pulsatile-flow LVADs on myocardial structure and function in this population. METHODS AND RESULTS Sixty-one patients who underwent LVAD implantation as bridge-to-transplant were analyzed (pulsatile-flow LVAD: group P, n=31; continuous-flow LVAD: group C, n=30). Serial echocardiograms, serum levels of brain natriuretic peptide (BNP), and extracellular matrix biomarkers (ECM) were compared between the groups. Myocardial BNP and ECM gene expression were evaluated in a subset of 18 patients. Postoperative LV ejection fraction was greater (33.2±12.6% versus 17.6±8.8%, P<0.0001) and the mitral E/E' was lower (9.9±2.6 versus 13.2±3.8, P=0.0002) in group P versus group C. Postoperative serum levels of BNP, metalloproteinases (MMP)-9, and tissue inhibitor of MMP (TIMP)-4 were significantly lower in group P compared with group C (BNP: 552.6±340.6 versus 965.4±805.7 pg/mL, P<0.01; MMP9: 309.0±220.2 versus 475.2±336.9 ng/dL, P<0.05; TIMP4: 1490.9±622.4 versus 2014.3±452.4 ng/dL, P<0.001). Myocardial gene expression of ECM markers and BNP decreased in both groups; however, expression of TIMP-4 decreased only in group P (P=0.024). CONCLUSIONS Mechanical unloading of the failing myocardium using pulsatile devices is more effective as indicated by echocardiographic parameters of systolic and diastolic LV function as well as dynamics of BNP and ECM markers. Therefore, specific effects of pulsatile mechanical unloading on the failing myocardium may have important implications for device selection especially for the purpose of bridge-to-recovery in patients with advanced HF.
منابع مشابه
Molecular normalization of dystrophin in the failing left and right ventricle of patients treated with either pulsatile or continuous flow-type ventricular assist devices.
OBJECTIVES We investigated the integrity of dystrophin in left ventricle (LV) and right ventricle (RV) of patients with end-stage heart failure due to ischemic cardiomyopathy (IHD) or dilated cardiomyopathy (DCM), and compared the efficacy of pulsatile or continuous flow assist devices on dystrophin reverse remodeling. BACKGROUND Recently we demonstrated that the amino (N)-terminus of dystrop...
متن کاملHemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...
متن کاملA mathematical model to evaluate control strategies for mechanical circulatory support.
Continuous flow ventricular assist devices (VADs) for mechanical circulatory support (MCS) are generally smaller and believed to be more reliable than pulsatile VADs. However, regarding continuous flow, there are concerns about the decreased pulsatility and ventricular unloading. Moreover, pulsatile VADs offer a wider range in control strategies. For this reason, we used a computer model to eva...
متن کاملLeft ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...
متن کاملIs flow really continuous in last generation continuous flow Ventricular Assist Devices? A comparison between HeartMate II and HeartWare HVAD
HSR Proceedings in Intensive Care and Cardiovascular Anesthesia 2011, Vol. 4 Corresponding author: Giulio Melisurgo Cardiovascular and Thoracic Department Università Vita-Salute San Raffaele Via Olgettina, 60 20132 Milan, Italy e-mail: [email protected] Continuous-flow ventricular assist devices (VADs) are the standard of care for implantable mechanical circulatory support (1). However, s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Heart failure
دوره 4 5 شماره
صفحات -
تاریخ انتشار 2011