Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

نویسندگان

  • Jongmin J. Lee
  • Yongmin Chang
  • Duk-Sik Kang
چکیده

OBJECTIVE To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. MATERIALS AND METHODS In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose time intensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. RESULTS Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. CONCLUSION Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-dose Contrast-enhanced Magnetic Resonance Angiography with Less than the Standard Dose of Gadolinium Chelate: Comparison with Conventional Digital Subtraction Angiography

angiography, various performance enhancing MR sequences and scanning protocols have been adopted (17). The development of higher performance MR scanners has facilitated these trials (5, 8, 9), and contrast-enhanced MR angiography (CEMRA) has thus become a feasible method of vascular imaging. Various amounts of contrast media have been used for CEMRA, ranging from the standard dose of 0.05 mmol ...

متن کامل

MRA contrast bolus timing with ultrasound bubbles.

The purpose of this study was to determine the feasibility of using an ultrasound contrast agent test bolus to determine optimum bolus timing for three-dimensional (3D) gadolinium (Gd)-enhanced magnetic resonance angiography (MRA). Small test doses of ultrasound contrast agent (0.3 ml Optison) were injected intravenously followed immediately by a 20 ml saline flush. Arrival of the contrast agen...

متن کامل

Magnetic Resonance Angiography Techniques

■ ■ Contrast-Enhanced Magnetic Resonance Angiography t1 Shortening phase encoding Considerations acquisition timing acquisition timing: test Bolus acquisition timing: Signal Initiated acquisition acquisition timing: Dynamic Subtraction Contrast-enhanced Magnetic resonance angiography Imaging parameters advantages of Contrast-enhanced Magnetic resonance angiography Limitations of Contrast-enhanc...

متن کامل

A Comparison of Low-Dose and Normal-Dose Gadobutrol in MR Renography and Renal Angiography

OBJECTIVE It has been advocated that a reduced injection volume with highly concentrated (1 M) contrast material can produce a sharper bolus peak and an increased intravascular first-pass gadolinium concentration when compared with the use of a lower concentration (0.5 M). A higher concentration would also cause a reduction in dose. The purpose of our study was to test the use of a low dose (0....

متن کامل

Gadolinium-enhanced, vessel-tracking, two-dimensional coronary MR angiography: single-dose arterial-phase vs. delayed-phase imaging.

The purposes of our study were to investigate the benefits of using a single dose of an extracellular contrast agent for coronary magnetic resonance angiography (CMRA) and to determine the relative benefits of arterial-phase vs. delayed-phase image acquisition. The right coronary artery was imaged in 10 healthy adults using a breath-hold, two-dimensional fast gradient echo pulse sequence design...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2000