Method to evaluate the dustiness of pharmaceutical powders.
نویسندگان
چکیده
The trend among pharmaceutical companies to develop selective drugs of high potency has pushed the industry to consider the potential of each hazardous ingredient to become airborne. Dustiness issues are not unique to the pharmaceutical industry, but are relevant to any industry where powdered materials are mixed, transferred and handled. Interest in dustiness is also driven by concerns for worker health, the potential for plant explosions and the prevention of product loss. Unlike other industries, the pharmaceutical industry is limited by the milligram quantity of powdered material available for testing during product development. These needs have led to the development of a bench-top dustiness tester that requires only 10 mg of powder and fully contains the generated aerosol. The powder is dispersed within a 5.7 liter glass chamber that contains a respirable mass sampler and a closed-face sampler to quantify the respirable and total dust that are generated with a given energy input. The tester distinguished differences in dustiness levels of five different powders. Finer powders were dustier, and the respirable dust percentage was always less than that for total dust. Four testers have been built and evaluated using pharmaceutical grade lactose. Dustiness measurements determined using all four testers were comparable. The pharmaceutical industry uses surrogates such as lactose to represent active compounds in tests that estimate the dust concentration likely to occur in a new manufacturing operation. Differences between the dustiness of the active compound and its surrogate challenge the relevance of the surrogate tests to represent true exposures in the workplace. The tester can determine the dustiness of both the active compound and its surrogate, and the resultant ratio can help to interpret dust concentrations from surrogate tests. Further, dustiness information may allow the pharmaceutical researcher to select powder formulations that present low airborne concentrations in the workplace.
منابع مشابه
Dustiness of Fine and Nanoscale Powders
Dustiness may be defined as the propensity of a powder to form airborne dust by a prescribed mechanical stimulus; dustiness testing is typically intended to replicate mechanisms of dust generation encountered in workplaces. A novel dustiness testing device, developed for pharmaceutical application, was evaluated in the dustiness investigation of 27 fine and nanoscale powders. The device efficie...
متن کاملA novel device for measuring respirable dustiness using low-mass powder samples.
Respirable dustiness represents the tendency of a powder to generate respirable airborne dust during handling and therefore indicates the propensity for a powder to become an inhalation hazard. The dustiness of 14 powders, including 10 different nanopowders, was evaluated with the use of a novel low-mass dustiness tester designed to minimize the use of the test powder. The aerosol created from ...
متن کاملComment on Comparison of Powder Dustiness Methods
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/ by/3.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. Editorial Note. Letters to the Editor are peer reviewed to ensure that the arguments are reasonable and clearly expresse...
متن کاملSize selective dustiness and exposure; simulated workplace comparisons.
A simulated workplace study was conducted to investigate the relation between inhalation exposure and dustiness determined with a rotating drum dustiness tester. Three powders were used in the study, i.e. magnesium stearate, representing a very dusty powder, and aluminium oxide and calcium carbonate, representing low and very low dusty powders, respectively. Two scenarios of handling small volu...
متن کاملCombined single-drop and rotating drum dustiness test of fine to nanosize powders using a small drum.
A dustiness test has been developed that performs both a single-drop and a continuous rotation test using a 6-g sample. Tests were completed on pigment-grade and ultrafine TiO2, two grades of corundum (Aloxite), yttrium-stabilized zirconia (Y-zirconia) granules, fumed silica, goethite, talc and bentonite. The generated particles were quantified by counting and sizing at 1-s time resolution usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 50 5 شماره
صفحات -
تاریخ انتشار 2006