Mass-sensing, multianalyte microarray immunoassay with imaging detection.

نویسندگان

  • J W Silzel
  • B Cercek
  • C Dodson
  • T Tsay
  • R J Obremski
چکیده

Miniaturization of ligand binding assays may reduce costs by decreasing reagent consumption, but it is less apparent that miniaturized assays can simultaneously exceed the sensitivity of macroscopic techniques by analyte "harvesting" to exploit the total analyte mass available in a sample. Capture reagents (avidin or antibodies) immobilized in 200-microm diameter zones are shown to substantially deplete analyte from a liquid sample during a 1-3-h incubation, and the assays that result sense the total analyte mass in a sample rather than its concentration. Detection of as few as 10(5) molecules of analyte per zone is possible by fluorescence imaging in situ on the solid phase using a near-infrared dye label. Single and multianalyte mass-sensing sandwich array assays of the IgG subclasses show the sensitivity and specificity of ELISA methods but use less than 1/100 the capture antibody required by the 96-well plate format.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of antibody-based microarray assay for quantitative detection of aflatoxin B1

BACKGROUND: Aflatoxin B1 (AFB1) is a toxic metaboliteproduced by Aspergillus species that contaminates a wide range ofagricultural products. OBJECTIVES: This study was designed todevelop a rapid and highly sensitive immunoassay method inmicroarray format for quantitative detection of AFB1 to evaluatethe potential of microarray platform for high-throughput screening,which can be beneficial in fo...

متن کامل

A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...

متن کامل

Imaging surface plasmon resonance for multiplex microassay sensing of mycotoxins

A prototype imaging surface plasmon resonance-based multiplex microimmunoassay for mycotoxins is described. A microarray of mycotoxin-protein conjugates was fabricated using a continuous flow microspotter device. A competitive inhibition immunoassay format was developed for the simultaneous detection of deoxynivalenol (DON) and zearalenone (ZEN), using a single sensor chip. Initial in-house val...

متن کامل

Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers.

A novel flow-through immunosensing system for performing a multianalyte chemiluminescent determination in a single run was designed. A new analytical strategy of substrate zone-resolved technique was proposed. Using carcinoma antigen 125 (CA 125) and carcinoembryonic antigen (CEA) as model analytes, the capture antibodies for CA 125 and CEA were immobilized on an UltraBind aldehyde-activated me...

متن کامل

Simultaneous Determination of -Fetoprotein and Free -Human Chorionic Gonadotropin by Element-Tagged Immunoassay with Detection by Inductively Coupled Plasma Mass Spectrometry

Background: An inductively coupled plasma mass spectrometry (ICP-MS)-based immunoassay has been proposed independently by Baranov et al. (Anal Chem 2002;74:1629–36) and our group, but the applicability of this method for multianalyte analysis in clinical samples has not been fully illustrated. We developed a dual-label immunoassay method for the simultaneous determination of -fetoprotein (AFP) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 1998