Increased late complex device infections are determined by cardiac resynchronization therapy-defibrillator infection.
نویسندگان
چکیده
AIMS The incidence of cardiac device infection (CDI) more than 12 months following complex device implant (late infection) has not been extensively reported. Our objective was to compare both early (within 12 months) and late infection rates following complex device implantation. METHODS AND RESULTS Patients who received either a cardiac resynchronization therapy (CRT) device with or without a defibrillator (CRT-D or CRT-P), or a defibrillator alone [implantable cardioverter-defibrillator (ICD)], between March 2005 and December 2011 were studied retrospectively. The study endpoint was device removal due to CDI. A total of 496 patients underwent complex device implantation. There were 1883 patient years of follow-up. Mean age was 73 ± 8 years. Seventy per cent were male. Overall, 24 infections (4.8%) were identified; 6 infections were within 12 months (1.2%) and 18 (3.7%) infections at least 12 months following implant (P < 0.025). The mean intervals between implant and infection were 6 months (±3.7) and 30 months (±14.4) in the early and late groups, respectively. Early infection rates (%) for ICD, CRT-P, and CRT-D devices were 1.5, 1.6, and 0.6, respectively. Corresponding late infection rates were 2.2, 2.1, and 6.4. The increased late infection rate was driven by increased CRT-D infection (P < 0.01; compared with early CRT-D infection). CONCLUSION Early CDI rates are consistent with published data. Compared with early infection, late CDI rates are significantly increased and are due to CRT-D infection. These findings are consistent with emerging reports. Late CRT-D infection threatens to undermine the long-term costs and overall health gain from these devices.
منابع مشابه
Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملThe wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections
BACKGROUND The approach to treat device infection in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) is a challenging procedure. Optimal treatment is complete extraction of the infected device. To protect these patients from sudden cardiac arrest while waiting for reimplantation and to avoid recurrent infection, a wearable ca...
متن کاملCardiac electrical device-related bacterial infections: Prevention, diagnosis, and management
Significant developmentin modern cardiac (or cardiovascular) electrical devices (CIEDs), including permanent pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy, is contributing to the improvement in both the survival rate and quality of life in patients with cardiac arrhythmias and/or heart failure. The number of CIED implantations has increased si...
متن کاملAdvances in Arrhythmia and Electrophysiology Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections
Advancements in our understanding of cardiac conduction abnormalities and pathophysiology of congestive heart failure coupled with innovations in device manufacturing and programming have helped to create a demand for a plethora of newer cardiovascular devices over the past 3 decades. Appropriate use of cardiovascular implantable electronic devices (CIEDs) in carefully selected patients is asso...
متن کاملMultiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
Inappropriate shocks from implantable cardioverter-defibrillators (ICDs) may occur for many reasons. Inappropriate shocks are not simply painful inconveniences for patients; they also may result in the need for further operative procedures, and sometimes even death. Herein, we report the case of a patient who after upgrade of an ICD to a cardiac resynchronization therapy-defibrillator device (C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 17 11 شماره
صفحات -
تاریخ انتشار 2015