Automated blood group serology.

نویسنده

  • G H Tovey
چکیده

Although automation was introduced into biochemistry in 1957 (Skeggs, 1957), it was not until 1963 that McNeil, Helrick, and Ferrari (1963) first described a mechanized technique forABO grouping. This was followed a few months later by a method employing the AutoAnalyzer continuous flow principle by which up to 40 samples per hour could be both ABO and Rh (D) grouped (Sturgeon, Cedergren, and McQuiston, 1963). During the succeeding six years developments have been such that blood samples can now be ABO grouped by machine, Rh typed, screened for irregular blood group antibodies, and some of the subtypes determined at a rate of one sample per 30 seconds, or 120 samples per hour. This is accomplished by a multichannel machine. There is also available a single-channel AutoAnalyzer for use in screening and quantitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guidelines on Establishing an EQA Scheme in Blood Group Serology

World Health Organization. External quality assessment of transfusion laboratory practice: guidelines on establishing an EQA scheme in blood group serology.

متن کامل

Automated blood group serology GEOFFREY

Although automation was introduced into biochemistry in 1957 (Skeggs, 1957), it was not until 1963 that McNeil, Helrick, and Ferrari (1963) first described a mechanized technique forABO grouping. This was followed a few months later by a method employing the AutoAnalyzer continuous flow principle by which up to 40 samples per hour could be both ABO and Rh (D) grouped (Sturgeon, Cedergren, and M...

متن کامل

Mechanized blood grouping: a hospital trial using an 8-channel grouping machine.

ABO and Rh (D) groups of 6403 blood samples were assessed on an 8/9-channel autoanalyser in the Serology Department of the London Hospital; the results were independently checked at the Regional Blood Transfusion Centre, Brentwood, using the routine methods for grouping donor blood. Results of this comparative study are given and instances are described in which anomalous results or incorrect g...

متن کامل

Automated complement fixation test for the detection of anti-trypanosoma cruzi antibodies.

An automated method to detect TrypanosomÐ crozi antibodies is described, using complement fixation with an adequate automated equipment. Fifty five serum samples from patients lvhere Trypanosoma cruzi antiþodies were detected by Almeida's technique for complement fixation and by fndirect Immunofluorescence test, were studied by this method. The conclusion is that this automated üechnique can be...

متن کامل

Effects of oral administration of Zataria multiflora essential oil on some blood and serum parameters in Acipenser persicus

In order to does this study, 150 Persian sturgeons having 75g mean weight transferred to 500 liter tanks. After dividing the fishes into two groups (experimental and control), the fingerlings fed by concentrate food that contained different levels of Zataria multiflora essential oil (15, 25, 50, 100 g/kg) for 8 weeks. Finally, sampling carried out on blood and serum of fishes. After preparing t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology. Supplement

دوره 3  شماره 

صفحات  -

تاریخ انتشار 1969