Demonstration of Nautilus Centripetal Capillary Condenser Technology

نویسندگان

  • Richard Wheeler
  • Linh Tang
  • Eric Golliher
  • Juan Agui
چکیده

This paper describes the results of a proof of concept effort for development of a Nautilus Centripetal Capillary Condenser (NCCC or NC) used for microgravity compatible water recovery from moist air with integral passive phase separation. Removal of liquid condensate from the air stream exiting a condenser is readily performed here on Earth. In order to perform this function in space however, without gravity or mechanical action, other tactics including utilization of inertial, drag and capillary forces are required. Within the NC, liquid water forms via condensation on cold condenser surfaces as humid air passes along multiple spiral channels, each in its own plane, all together forming a stacked plate assembly. Non-mechanical inertial forces are employed to transfer condensate, as it forms, via centripetal action to the outer perimeter of each channel. A V-shaped groove, constructed on this outer edge of the spiral channel, increases local capillary forces thereby retaining the liquid. Air drag then pulls the liquid along to a collection region near the center of the device. Dry air produced by each parallel spiral channel is combined in a common orthogonal, out-of-plane conduit passing down the axial center of the stacked device. Similarly, the parallel condensate streams are combined and removed from the condenser/separator through yet another out-of-plane axial conduit. NC is an integration of conventional finned condenser operation, combined with static phase separation and capillary transport phenomena. A Mars’ transit mission would be a logical application for this technology where gravity is absent and the use of vibrating, energy-intensive, motordriven centrifugal separators is undesired. Here a vapor stream from either the Heat Melt Compactor or the Carbon dioxide Reduction Assembly, for example, would be dried to a dew point of 10 oC using a passive NC condenser/separator with the precious water condensate recycled to the water bus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Testing of a Planar, Silicon Mini-Capillary Pumped Loop

A planar, silicon mini capillary pumped loop (CPL) was designed, built, and tested using recent MEMS technology to provide integral cooling and temperature control for electronics. This design featured three silicon fusion bonded wafers incorporating an evaporator, condenser, liquid line and vapor line, all of which were dry plasma etched. Grooves were etched in the condenser and evaporator to ...

متن کامل

Reflection mode imaging with nanoscale resolution using a compact extreme ultraviolet laser.

We report the demonstration of reflection mode imaging of 100 nm-scale features using 46.9 nm light from a compact capillary-discharge laser. Our imaging system employs a Sc/Si multilayer coated Schwarzschild condenser and a freestanding zone plate objective. The reported results advance the development of practical and readily available surface and nanostructure imaging tools based on the use ...

متن کامل

Tactical High Energy Laser

The Nautilus Project was started in 1995 as a joint USIsrael feasibility study for using laser systems to defend against short-range artillery rockets. It has now matured into a successful laser weapon demonstration program – the Tactical High Energy Laser (THEL) Advanced Concept Technology Demonstration (ACTD) Program. By now the THEL Demonstrator has engaged and destroyed a large number of ar...

متن کامل

Hard X-ray Imaging Microscopy using X-ray Guide Tube as Beam Condenser for Field Illumination

An optical system for illumination of object in x-ray imaging microscopy is developed. The optical system is a beam condenser consisting of a single-bounce conical-shape mono-capillary (x-ray guide tube: XGT) made of Pyrex glass. The XGT condenser was tested at the beam line 47XU of SPring-8 using a Fresnel zone plate as an objective lens. Comparing with the microscope without beam condenser, t...

متن کامل

Selection of Capillary Tube for Refrigeration System

Proper selection of capillary tube it is essential to study the effect of capillary tube geometry on the performance of refrigeration systems. The literature review is focused on the influence of geometrical parameters like tube length, diameter, coil pitch, number of twist and twisted angle on pressure drop and coefficient of performance (COP) of the system. These parameters can be optimized u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016