An observational study comparing the prototype device with the existing device for the effective visualization of invisible veins in elderly patients in Japan
نویسندگان
چکیده
OBJECTIVE To compare the performance on the detection of the invisible veins between our modified prototype device and an existing device in elderly hospitalized patients. METHODS A prospective, cross-sectional, and observational study was performed in the invisible veins in elderly patients. The major variables, skin color near the invisible veins, and diameter and depth of the invisible veins were measured. The vein visualization rate was calculated as the ratio of the visualized veins to the invisible veins by the visualization device. RESULTS We analyzed 53 invisible veins in the cubital fossa and 56 invisible veins in the forearm in a total of 72 patients (median age, 73 years). The visualization rate for our prototype device was higher than that for an existing device in the cubital fossa and the forearm sites. The visualized veins of the prototype device had a higher intensity ratio than that of an existing device. No significant differences were observed in the body mass index, vein depth, and vein diameter of the visualized veins at the cubital fossa and forearm sites. CONCLUSION The prototype surpassed the existing device in visualizing the invisible veins. However, the prototype was unable to visualize all the invisible veins. We need to look for ways to reduce noise and to visualize the invisible veins, and the visualization rate of devices needs to be investigated in further association with the percentage of success with actual intravenous access and locating time to vein.
منابع مشابه
Design and Implementation of an Automated Dispensing Device for Reducing Methadone Therapy Misuse
Introduction: A variety of (deliberate or inaccurate) errors in drug rehabilitation clinics may occur due to use of addictive drugs. Automated drug distribution systems play a significant role in reducing drug medication errors. Method: Firstly, according to the addiction rehabilitation centers requests, the design and construction of the device was performed. The prototype systems were examin...
متن کاملAutonomous Wireless Heat Energy Meter based on Piezoelectric Energy Harvester for Heat Energy Measurement in Building Complexes
This paper presents a platform for power autonomous wireless energy meter device using piezoelectric energy harvesters. This device can be mainly used for measuring the share of heat energy consumption in a fair manner in building complex with central heat energy system. In the suggested device, the piezoelectric energy harvester is also used as a flow-meter to reduce the power consumption of t...
متن کاملDesign and Manufacture of a Smart Orthopedic Pin Cutter for Use in the Operating Room and Patients Undergoing Orthopedic Surgery
Background and Aim: Since pin cutter is used in surgical operations involving screw and orthopedic plating and this is one of the most sensitive surgeries, saving time is very important along with reducing infection rate. The purpose of design the Mini-Pin Cutter is to replace a smaller, lighter, more efficient device than conventional and traditional cutters, which ultimately results in a comf...
متن کاملDesign and fabrication of portable motion recorder: comparing lumbar kinematics in workers with and without low back pain in assembly line of a car manufacturing industry
Introduction: Workers in car manufacturing industry are at risk of a high prevalence of musculoskeletal disorders, especially low back pain. Therefore, in the present study aimed to design and fabricate a portable device to evaluate the low back kinematics and to compare these variables in workers with and without low back pain (LBP) in assembly lines of an automotive industry. Material and Me...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کامل