Distortion correction of body diffusion weighted images using three point-Dixon method

نویسندگان

  • S. Mori
  • I. Muro
  • H. Moriguchi
  • T. Horie
  • M. Honda
  • T. Ogino
  • M. Obara
  • Y. Imai
چکیده

Introduction: Significant distortion can often be observed in body diffusion weighted images (DWI) using single shot EPI. Distortion is caused by external magnetic field (B0) inhomogeneity. The degree of distortion is proportional to B0. When a precise B0 map is obtained, distortion can be corrected using the B0 map. In this study, we demonstrate that a B0 map obtained using three point-Dixon method is useful to correct for distortion. Clinical images corrected using this method are also shown. Method: A flow chart of our proposed method is shown in Fig.2. In this method, we applied five low pass filters to a B0 map. Only pass bands of these low pass filters were varied. Distortion correction was done using these five B0 maps. A final corrected image was selected from these five corrected images. We calculated correlation coefficients between each corrected image and the combined water and fat image. A corrected image that produced the highest correlation coefficient was chosen as the final image. We performed both phantom and volunteer scanning to test our proposed method. In phantom study, we scanned a column phantom filled with water (Fig.1) using eight channel phased array coils. The size of the phantom was 380mm x 380mm x 100mm. Details of scanning parameters were: FOV 400mm, slice thickness/gap 4/0mm, #slices 100, NEX 2~10, SENSE acceleration factor 2, image matrix size 256 x 256. We used three types of pulse sequences in this experiment. Parameters of these sequences are as follows. Sequence 1: single shot EPI TR/TE 7000/60msec; Sequence 2: three echoGRE (Dixon methods) #phase encoding (PE) steps 32, TR/TE 2500/3.2x3msec; Sequence 3: three echoGRE (Dixon methods) #PE steps 128, TR/TE 2500/3.2x3msec. We created water and fat images, a B0 map and the combined water and fat image using the sequences 2 and 3. We performed distortion correction for 100 axial images. Two types of B0 maps were created using sequences 2 and 3. They differed in resolutions. Correction was done based on each B0 map. A sagittal multiplanar reformatted image was created using both of these corrected images. We made comparison on preciseness of the correction between these B0 maps. In in-vivo study, we scanned asymptomatic volunteers. DWI of pelvis and spinal cords of the volunteers were scanned using eight channel phased array coils. b-value was set to 800s/mm2. We used the same pulse sequences as Sequences 2 and 3 described above in this experiment. Results: In phantom study, there was no significant difference between the images corrected using the B0 map with 32 PEs and those corrected using the B0 map with 128 PEs.(Fig3) The correlation coefficients of both corrected images were increased by 0.01 or greater from those of the uncorrected images. In in-vivo study, significant improvements of distortion correction were observed in both spinal cord and pelvis images.(Fig4) Discussion: In three point-Dixon method, good distortion correction is achieved using the sequence with 32 PEs. In this method, although prescan is required, it requires about a minute and a B0 map obtained from the prescan can be applied to 50 images. This method is quite useful in practice since a B0 map created using this method enables good distortion correction. Acknowledgements: We thank Philips Electronics Japan for providing us 3 pt-DIXON(WIP). 3echo-GRE Image reconstruction

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of B0 susceptibility induced distortion in diffusion-weighted images using large-deformation diffeomorphic metric mapping.

Geometric distortion caused by B0 inhomogeneity is one of the most important problems for diffusion-weighted images (DWI) using single-shot, echo planar imaging (SS-EPI). In this study, large-deformation, diffeomorphic metric mapping (LDDMM) algorithm has been tested for the correction of geometric distortion in diffusion tensor images (DTI). Based on data from nine normal subjects, the amount ...

متن کامل

Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization

Diffusion MRI provides quantitative information about microstructural properties which can be useful in neuroimaging studies of the human brain. Echo planar imaging (EPI) sequences, which are frequently used for acquisition of diffusion images, are sensitive to inhomogeneities in the primary magnetic (B0) field that cause localized distortions in the reconstructed images. We describe and evalua...

متن کامل

Susceptibility Distortion Correction for Echo Planar Images with Non-uniform B-Spline Grid Sampling: A Diffusion Tensor Image Study

In this paper, we propose a novel method for correcting the geometric distortions in diffusion weighted images (DWI) obtained with echo planar imaging (EPI) protocol. Our EPI distortion correction approach employs a deformable registration framework with the B-splines transformation, where the control point distributions are non-uniform and functions of the expected norm of the spatial distorti...

متن کامل

Characterization and Correction of Geometric Distortions in 814 Diffusion Weighted Images.

INTRODUCTION Diffusion Weighted Imaging (DWI), which is based on Echo Planar Imaging (EPI) protocols, is becoming increasingly important for neurosurgical applications. However, its use in this context is limited in part by significant spatial distortion inherent to EPI. METHOD We evaluated an efficient algorithm for EPI distortion correction (EPIC) across 814 DWI scans from 250 brain tumor p...

متن کامل

Accounting for Changes in Signal Variance in Diffusion Weighted Images Following Interpolation for Motion and Distortion Correction

Introduction: Processing of clinical diffusion weighted images (DWIs) for Diffusion Tensor Imaging (DTI) and other applications requires correction for motion, eddy current distortions [1], and susceptibility induced EPI distortions [2]. These corrections are obtained by image registration techniques followed by interpolation of the original images. Image interpolation, however, alters the nois...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009