Success rate, healing time, and implant stability of photofunctionalized dental implants.

نویسندگان

  • Akiyoshi Funato
  • Masahiro Yamada
  • Takahiro Ogawa
چکیده

PURPOSE This is the first study to report the clinical outcomes of photofunctionalized dental implants. MATERIALS AND METHODS This retrospective study analyzed 95 consecutive patients who received 222 untreated implants and 70 patients who received 168 photofunctionalized implants over a follow-up period of 2.5 years. Photofunctionalization was performed by treating implants with UV light for 15 minutes using a photo device immediately before placement. The generation of superhydrophilicity and hemophilicity along with a substantial reduction in atomic percentage of surface carbon was confirmed after photofunctionalization. In both groups, 90% of the implants were placed in complex cases requiring staged or simultaneous site-development surgery. The implant stability was measured at implant placement and loading using the implant stability quotient (ISQ) values; then, the rate of implant stability development was evaluated by calculating the ISQ increase per month. RESULTS The healing time before functional loading was 3.2 months in photofunctionalized implants and 6.5 months in untreated implants. The success rate was 97.6% and 96.3% for photofunctionalized and untreated implants, respectively. The ISQ increase per month for photofunctionalized implants ranged from 2.0 to 8.7 depending on the ISQ at placement, and it was considerably higher than that of untreated implants reported in the literature ranging from -1.8 to 2.8. Photofunctionalization resulted in a more frequent use of implants of 10 mm or shorter length and an overall decrease in implant diameter. CONCLUSIONS Within the limits of this retrospective study, despite the more frequent use of shorter and smaller-diameter implants, the use of photofunctionalization allowed for a faster loading protocol without compromising the success rate. The outcome was associated with an increased rate of implant stability development. The results suggest that photofunctionalization may provide a novel and practical avenue to further advance implant therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant stability change and osseointegration speed of immediately loaded photofunctionalized implants.

OBJECTIVES This study evaluated the degree and rate of implant stability development for photofunctionalized dental implants in humans. MATERIALS AND METHODS Thirty-three implants (7 patients) placed in the maxilla and immediate loaded were evaluated. Photofunctionalization was performed by treating implants with ultraviolet for 15 minutes immediately before placement. Implant stability was a...

متن کامل

Success rate of immediate loading of single OPILS implants of Neo-Dent system

Success rate of immediate loading of single OPILS implants of Neo-Dent system Dr. SH. Namjoy Nik * - Dr. SH. Shahab ** - Dr. M. Mohammad Poor*** - Dr. A. Balooch*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry – Shahed University. **- Assistant Professor of Oral Radiology Dept. Faculty of Dentistry – Shahed University. ***- Dentist. Background and Aim: I...

متن کامل

Photofunctionalized dental implants: a case series in compromised bone.

PURPOSE Ultraviolet (UV) light treatment of titanium, or photofunctionalization, has been shown to enhance its osteoconductivity in animal and in vitro studies, but its clinical performance has yet to be reported. This clinical case series sought to examine the effect of photofunctionalization on implant success, healing time, osseointegration speed, and peri-implant marginal bone level changes...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2013