Improving wedged field dose distributions.

نویسندگان

  • P Keall
  • S Zavgorodni
  • L Schmidt
  • D Haskard
چکیده

Dose profiles produced by wedge filters in the non-wedged direction can exhibit a 7% or greater dose reduction at the outer ends of the field compared with open field profiles. However, many planning systems use open field profiles to model wedged dose distributions. In the present work, wedges have been modified to reproduce open field profile shapes. This modification involved removing varying thicknesses of the wedge using a simple milling machine. The wedge thickness was calculated using the assumption that dose is proportional to primary collision kerma. The discrepancies in dose between wedged field and open field profile shapes of up to 7% were reduced to less than 3% with the modifications, even for varying depths and off-axis distances. The necessary measurements are simple to perform, and hence this technique could be applied to improve wedged field dose distributions in other radiotherapy departments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

متن کامل

Calculation of wedged dose distributions using an analytical method

Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...

متن کامل

The impact of dose calculatıon algorıthms for perıpheral dose dıstrıbutıons of enhanced dynamıc and physıcal wedges

Background: In radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculation algorithms of the Varian Eclipse 8.6 treatment planning system(TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC) was used to compare measured and calculated peripheral dose distributi...

متن کامل

Quantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

متن کامل

Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge

The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distribution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 42 11  شماره 

صفحات  -

تاریخ انتشار 1997