Performance of Multiplex Commercial Kits to Quantify Cytokine and Chemokine Responses in Culture Supernatants from Plasmodium falciparum Stimulations
نویسندگان
چکیده
BACKGROUND Cytokines and chemokines are relevant biomarkers of pathology and immunity to infectious diseases such as malaria. Several commercially available kits based on quantitative suspension array technologies allow the profiling of multiple cytokines and chemokines in small volumes of sample. However, kits are being continuously improved and information on their performance is lacking. METHODOLOGY/PRINCIPAL FINDINGS Different cytokine/chemokine kits, two flow cytometry-based (eBioscience® FlowCytomix™ and BD™ Cytometric Bead Array Human Enhanced Sensitivity) and four Luminex®-based (Invitrogen™ Human Cytokine 25-Plex Panel, Invitrogen™ Human Cytokine Magnetic 30-Plex Panel, Bio-Rad® Bio-Plex Pro™ Human Cytokine Plex Assay and Millipore™ MILLIPLEX® MAP Plex Kit) were compared. Samples tested were supernatants of peripheral blood mononuclear cells of malaria-exposed children stimulated with Plasmodium falciparum parasite lysates. Number of responses in range that could be detected was determined and reproducibility of duplicates was evaluated by the Bland-Altman test. Luminex® kits performed better than flow cytometry kits in number of responses in range and reproducibility. Luminex® kits were more reproducible when magnetic beads were used. However, within each methodology overall performance depended on the analyte tested in each kit. Within the Luminex® kits, the Invitrogen™ with polystyrene beads had the poorer performance, whereas Invitrogen™ with magnetic beads had the higher percentage of cytokines/chemokines with both readings in range (40%), followed by Bio-Rad® with magnetic beads (35%). Regarding reproducibility, the Millipore™ kit had the highest percentage (60%) of cytokines/chemokines with acceptable limits of agreement (<30%), followed by the Invitrogen™ with magnetic beads (40%) that had tighter limits of agreement. CONCLUSIONS/SIGNIFICANCE Currently available kits for cytokine and chemokine quantification differ in reproducibility and concentration range of accurate detection. Luminex®-based kits with magnetic beads perform the best. Data highlights the importance of testing different kits before each study to choose the most appropriate, depending on the priority of the cytokines assessed.
منابع مشابه
RESISTANCE OF PLASMODIUM FALCIPARUM TO CHLOROQUINE IN SOUTH EASTERN IRAN
In vivo and in vitro assessments of the response of P. falciparum to chloroquine using WHO standard kits and techniques were carried out in I ran Shahr, Sistan and Baluchestan province of Iran in 1985. In the in vivo assessment, 24 malaria patients treated with chloroquine (25mg/kg over three days) were followed up for one to four weeks. The mean parasite clearance time was 4.3 days and in...
متن کاملThe Use of Crude Plasmodium falciparum Antigens for Comparison of Antibody Responses in Patients with Mild Malaria vs. Cerebral Malaria
Background: Cerebral malaria (CM) is one of the major causes of death in African populations infected with Plasmodium falciparum. Only 1% of infected subjects develop CM. The reasons for these differences are not fully understood, but it is likely that the host humoral response against blood-stage antigens plays a role in protection from malaria, although the precise targets and mechanisms medi...
متن کاملAn Evaluation of Commercial Fluorescent Bead-Based Luminex Cytokine Assays
The recent introduction of fluorescent bead-based technology, allowing the measurement of multiples analytes in a single 25-50 microl sample has revolutionized the study of cytokine responses. However, such multiplex approaches may compromise the ability of these assays to accurately measure actual cytokine levels. This study evaluates the performance of three commercially available multiplex c...
متن کاملPlasmodium falciparum infection causes proinflammatory priming of human TLR responses.
TLRs are a major group of pattern recognition receptors that are crucial in initiating innate immune responses and are capable of recognizing Plasmodium ligands. We have investigated TLR responses during acute experimental P. falciparum (P.f.) infection in 15 malaria-naive volunteers. TLR-4 responses in whole blood ex vivo stimulations were characterized by significantly (p < 0.01) up-regulated...
متن کاملClinical Pharmacology of the Antimalarial Chloroquine in Children and Their Mothers
Plasmodium falciparum, Plasmodium vivax, Plasmodium ovale, Plasmodium malariae, and Plasmodium knowlesi are the parasites that infect humans. Plasmodium falciparum and Plasmodium vivax cause most of the malarial infections worldwide. Plasmodium vivax, Plasmodium ovale, Plasmodium malariae, and Plasmodium knowlesi are susceptible to chloroquine. Chloroquine was the world's most widely used antim...
متن کامل