Fast spin-echo MR of contact points on implanted intracerebral stainless steel multicontact electrodes.
نویسندگان
چکیده
A three-dimensional fast spin-echo MR technique is proposed for locating contact points on implanted intracerebral multicontact electrode bundles, Coronal or sagittal reformatting shows the entire trajectory of the electrode bundles. The contract points are clearly visible owing to the absence of coating material associated with a slightly larger susceptibility artifact. Potentially, this technique may preclude postimplantation thin-section CT, with its associated high radiation dose.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملFerromagnetism and MR imaging: safety of carotid vascular clamps.
Metallic extracranial carotid vascular clamps of the Selverstone, Crutchfield, Poppen-Blaylock, Salibi, Kindt, and tantalum varieties have been placed for treatment of large, giant, or inoperable intracranial aneurysms. To ascertain what adverse effect, if any, MR imaging would have on these clamps, magnetic deflection at 1.5 T was measured for various carotid clamps. Marked magnetic deflection...
متن کاملElectrochemical Characterization of Microelectrodes for use in Cortical Tissue
Microelectrodes implanted in cortical tissue have been shown to effectively send and record electrical brain signals. The limitation encountered in the past is the robustness of these electrodes. New flexible electrodes are being developed to solve this problem, but electrochemical (EC) measurements are a required step in the characterization of these microelectrodes before they can be implante...
متن کاملComparison of T2-weighted and fluid-attenuated inversion-recovery fast spin-echo MR sequences in intracerebral AIDS-associated disease.
PURPOSE To compare the value of fast fluid-attenuated inversion-recovery (FLAIR) with T2-weighted fast spin-echo MR imaging in the detection of acquired immunodeficiency virus (AIDS)-related lesions of the brain. METHODS Forty-four human immunodeficiency virus (HIV)-positive patients were examined with both sequences on either a 1.0-T or a 1.5-T MR system. The number, size, location, and cons...
متن کاملDramatic Reduction of Dc Field Emission from Large Area Electrodes by Plasma-source Ion Implantation*
Field emission is one of the principal phenomena limiting the operating voltage of practical electron guns. There is interest in developing photoemission cathode based DC electron guns employing cathode field strengths and cathode-anode voltages well above the present stateof-the-art. Such electron sources could provide high brightness, high average current beams for energy recovered supercondu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 17 10 شماره
صفحات -
تاریخ انتشار 1996