Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo).

نویسندگان

  • S Bruley des Varannes
  • F Mion
  • P Ducrotté
  • F Zerbib
  • P Denis
  • T Ponchon
  • R Thibault
  • J P Galmiche
چکیده

OBJECTIVES Oesophageal pH monitoring is a useful test for the diagnosis of gastro-oesophageal reflux disease (GORD) but has some limitations related to the nasopharyngeal electrode. Recently, a telemetric catheter free system (CFS) (Bravo; Medtronic) was developed. The aim of this study was to determine the concordance of data between the conventional pH measurement system (CPHMS) and the CFS Bravo. METHODS Forty patients with symptoms suggestive of GORD underwent 24 hour oesophageal pH monitoring using the CPHMS with a nasopharyngeal electrode and the Bravo CFS simultaneously. The sensitive tips of both electrodes were positioned at the same level under fluoroscopy. In addition to automatic analysis, each reflux episode was checked visually and characterised. RESULTS There was a significant correlation (r = 0.87, p < 0.0001) between the 24 hour oesophageal acid exposures recorded by the CPHMS and the CFS. Twenty four hour oesophageal acid exposure was significantly lower with the CFS than with the CPHMS (2.4 (0.4-8.7) v 3.6 (0.7-8.6); p < 0.0001). Consequently, with the CFS, the cut off level for the diagnosis of GORD, as calculated from the regression equation, was 2.9% (for the 4.2% cut off determined in controls with the CPHMS). After this adjustment, concordance of the diagnosis of GORD was 88% (kappa 0.760). Diagnosis of GORD was established in more patients with the CFS 48 hour results than with the 24 hour results. CONCLUSIONS Despite strong correlations between oesophageal acid exposure recorded with the two devices, the Bravo CFS significantly under recorded acid exposure compared with the CPHMS. Provided some correcting factors are used, the Bravo CFS can improve the sensitivity of pHmetry for the diagnosis of GORD by allowing more prolonged recordings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capsule pH monitoring: is wireless more?

S ince its introduction in 1974, ambulatory oesophageal pH monitoring has secured a valuable but complementary role in the diagnosis of gastro-oesophageal reflux disease. Monitoring of oesophageal pH allows not only the detection of excessive levels of acid exposure but also, and more importantly, assessment of the relationship between acid reflux and symptoms. It is especially useful for clari...

متن کامل

[Outpatient monitoring of oesophageal pH with a catheter-free pH-meter (Bravo System). A Study of tolerance, safety and efficacy].

BACKGROUND AND OBJECTIVE A new catheter-free outpatient oesophageal pH-meter system (Bravo) has recently been developed. The objective of this study is to test the tolerance, safety and efficacy of the system in the measurement of gastric-oesophageal reflux by comparing it with a conventional pH system. PATIENTS AND METHOD The study was performed on a control group consisting of 10 healthy vo...

متن کامل

Reflux related symptoms in patients with normal oesophageal exposure to acid.

Several studies, using pH monitoring with event markers, have identified patients with normal oesophageal exposure to acid despite an apparent relation between symptoms and reflux episodes. In this series of 771 consecutive patients referred for 24 hour oesophageal pH monitoring, a probability calculation was used to evaluate the relation between symptoms and reflux episodes. Oesophageal exposu...

متن کامل

OESOPHAGUS Acid reflux event detection using the Bravo wireless versus the Slimline catheter pH systems: why are the numbers so different?

Objective: This study analysed the relative accuracy of the Bravo wireless and the Slimline catheter-Mark III Digitrapper pH systems in the detection of acid reflux events. Methods: Twenty five asymptomatic subjects were studied. A Bravo capsule was placed 6 cm above the squamocolumnar junction (SCJ), marked by an endoclip, and a Slimline pH catheter was placed 5 cm above the manometrically loc...

متن کامل

Acid reflux event detection using the Bravo wireless versus the Slimline catheter pH systems: why are the numbers so different?

OBJECTIVE This study analysed the relative accuracy of the Bravo wireless and the Slimline catheter-Mark III Digitrapper pH systems in the detection of acid reflux events. METHODS Twenty five asymptomatic subjects were studied. A Bravo capsule was placed 6 cm above the squamocolumnar junction (SCJ), marked by an endoclip, and a Slimline pH catheter was placed 5 cm above the manometrically loc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gut

دوره 54 12  شماره 

صفحات  -

تاریخ انتشار 2005