An optical tracker based robot registration and servoing method for ultrasound guided percutaneous renal access
نویسندگان
چکیده
BACKGROUND Robot-assisted needle steering facilitates the percutaneous renal access (PRA) for their accuracy and consistency over manual operation. However, inaccurate image-robot correspondence and uncertainties in robot parameters make the needle track deviate from the intrarenal target. This paper aims to simplify the image-tracker-robot registration procedure and improves the accuracy of needle alignment for robot assisted ultrasound-guided PRA. METHODS First, a semi-automatic rigid registration is used for the alignment of the preoperative MR volume and the intraoperative orthogonal US slices. Passive markers are mounted both on US probe and robot end-effector, the planned puncture path is transferred from the MR volume frame into optical tracker frame. Tracker-robot correspondence and robot calibration are performed iteratively using a simplified scheme, both position and orientation information are incorporated to estimate the transformation matrix, only several key structural robot parameters and joint zero-positions are calibrated for simplicity in solving the inverse kinematic. Furthermore, an optical tracker feedback control is designed for compensating inaccuracies in robot parameters and tracker-robot correspondence, and improving the accuracy of needle alignment. The intervention procedure was implemented by a telemanipulated 5R1P robot, two experiments were conducted to validate the efficiency of robot-tracker registration method and the optical tracker feedback control, robot assisted needle insertion experiment was conducted on kidney phantom to evaluate the system performance. RESULTS The relative positioning accuracy of needle alignment is 0.24 ± 0.08 mm, the directional accuracy is 6.78 ± 1.65 × 10⁻⁴rad; the needle-target distance of needle insertion is 2.15 ± 0. 17 mm. The optical tracker feedback control method performs stable against wide range of angular disturbance over (0 ~ 0.4) radians, and the length disturbance over (0 ~ 100) mm. CONCLUSIONS The proposed optical tracker based robot registration and servoing method is capable of accurate three dimension needle operation for PRA procedure with improved precision and shortened time.
منابع مشابه
Laparoscopic Assisted ultrasound guided Percutaneous Nephrolithotomy (PCNL) in Ectopic Pelvic Kidney
We report a patient with pain, abdominal palpable mass and a history of previous open renal stone surgery. Imaging studies showed a right pelvic kidney with multiple calyceal stones. We describe the successful management through laparoscopic assisted percutaneous nephrolithotomy with ultrasonography (PCNL) in ectopic pelvic kidney, stressing that this method is a minimally invasive therapeutic...
متن کاملMotion-Based Robotic Instrument Targeting under C-Arm Fluoroscopy
We present a simple and precise robot targeting method under portable x-ray fluoroscopy based on image servoing. The method is implemented for needle alignment in percutaneous procedures using the PAKY-RCM robot developed in our laboratory. Initial clinical tests apply to the access of the renal collecting system. Previously reported methods for computer assisted instrument targeting under fluo...
متن کاملAutomatic Targeting Method and Accuracy Study in Robot Assisted Needle Procedures
We present an automatic needle targeting method for fluoroscopyguided percutaneous access procedures. The approach is derived from the manual needle superimposition technique making it intuitive and familiar to surgeons and radiologists. The proposed algorithm is insensitive to image distortion and does not require any C-Arm calibration or initial pose estimation. Needle alignment is performed ...
متن کاملSkull registration for prone patient position using tracked ultrasound
PURPOSE: Tracked navigation has become prevalent in neurosurgery. Problems with registration of a patient and a preoperative image arise when the patient is in a prone position. Surfaces accessible to optical tracking on the back of the head are unreliable for registration. We investigated the accuracy of surface-based registration using points accessible through tracked ultrasound. Using ultra...
متن کاملComparison Between Open and Ultrasonography Guided Venous Access Ports in Children with Malignancy
Background: Long-term central venous access is used in children for various reasons specially for delivering chemotherapy. Since vessels in children have smaller diameters, they are more prone to injury and complications such as thrombosis. Different methods are used for implantation of port-a-cath in children. We aimed to compare the complications of insertion of central venous access ports be...
متن کامل