Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma.

نویسندگان

  • H Bisgaard
  • B Klug
  • B S Sumby
  • P K Burnell
چکیده

The study aimed to investigate dose consistency and particle distribution from the dry powder inhalers Diskus and Turbuhaler. Full profiles of inhalation pressure versus time were recorded in 18 4 yr old and 18 8 yr old asthmatic children through Diskus and Turbuhaler inhalers. These data were used in an inhalation profile simulator to assess drug delivery from both a Diskus inhaler and a Turbuhaler inhaler, and in particular to assess the proportion of drug emitted in the coarse (>4.7 microm) and fine (<4.7 microm) particle size range from each type of inhaler. The inhalation profile more accurately represents the changes in flow rate over time through the device than the constant flow rate usually applied with an impactor alone. The aerosol cloud was released before the peak inspiratory effort had been achieved and accordingly the early part and not the peak of the inspiratory performance is a determinant of the quality of the aerosol. The mean (SD) amount of drug in large particles (>4.7 microm), fine particles (<4.7 microm) and very fine particles (<2.1 microm) in percentage of label claim from the Fluticasone Diskus was 72 (5), 15 (2) and 2 (1) from the 4 yr old children and 71 (3), 18 (2) and 2 (1) from the 8 yr old children, respectively. Similar particle fractions from the Budesonide Turbuhaler were 35 (9), 21 (10) and 7 (5) from 4 yr old children and 30 (7), 32 (9) and 12 (6) from 8 yr old children. In conclusion, the Diskus inhaler provides an improved dose consistency through the varying age groups and inspiratory flow performances when compared to the Turbuhaler in terms of the proportion of the dose emitted at each particle size. This improvement is at the expense of a low fine particle mass and a high proportion of coarse particles from the Diskus as compared with the Turbuhaler.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventolin Diskus and Inspyril Turbuhaler: An In Vitro Comparison

Dose delivery (total emitted dose, or TED) from dry powder inhalers (DPIs), pulmonary deposition, and the biological effects depend on drug formulation and device and patient characteristics. The aim of this study was to measure, in vitro, the relationship between parameters of inhalation profiles recorded from patients, the TED and fine particle mass (FPM) of Diskus and Turbuhaler inhalers. In...

متن کامل

Ventolin Diskus and Inspyril Turbuhaler: an in vitro comparison.

Dose delivery (total emitted dose, or TED) from dry powder inhalers (DPIs), pulmonary deposition, and the biological effects depend on drug formulation and device and patient characteristics. The aim of this study was to measure, in vitro, the relationship between parameters of inhalation profiles recorded from patients, the TED and fine particle mass (FPM) of Diskus and Turbuhaler inhalers. In...

متن کامل

User error with Diskus and Turbuhaler by asthma patients and pharmacists in Jordan and Australia.

BACKGROUND Use of inhalers requires accurate completion of multiple steps to ensure effective medication delivery. OBJECTIVE To evaluate the most problematic steps in the use of Diskus and Turbuhaler for pharmacists and patients in Jordon and Australia. METHODS With standardized inhaler-technique checklists, we asked community pharmacists to demonstrate the use of Diskus and Turbuhaler. We...

متن کامل

Skills in Handling Turbuhaler, Diskus, and Pressurized Metered-Dose Inhaler in Korean Asthmatic Patients

PURPOSE The objective of this study was to evaluate skills in handling inhalers and factors associated with these skills among patients with asthma who had undergone treatment at special asthma and allergy clinics in Korea. METHODS We enrolled 78 subjects who used Turbuhaler and 145 who used Diskus for asthma control at special clinics in 10 university hospitals and visually assessed their sk...

متن کامل

[Measurement of inspiratory flow for the selection of the inhalation treatment device for asthma and COPD].

AIM To assess the proportion of patients with asthma or chronic obstructive pulmonary disease (COPD) with significant bronchoobstruction who do not have inspiratory flows necessary for the adequate use of dry powder inhaler (DPI) devices Diskus and Turbuhaler. PATIENTS AND METHODS multicentre cross-sectional study that included 400 patients with asthma or COPD (with FEV1 < 60%) aged 5-91 year...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 11 5  شماره 

صفحات  -

تاریخ انتشار 1998