The effect of nucleus implant parameters on the compressive mechanics of the lumbar intervertebral disc: a finite element study.

نویسندگان

  • Abhijeet Joshi
  • Christopher J Massey
  • Andrew Karduna
  • Edward Vresilovic
  • Michele Marcolongo
چکیده

A simplified finite element model of the human lumbar intervertebral disc was utilized for understanding nucleus pulposus implant mechanics. The model was used to assess the effect of nucleus implant parameter variations on the resulting compressive biomechanics of the lumbar anterior column unit. The effects of nucleus implant material (modulus and Poisson's ratio) and geometrical (height and diameter) parameters on the mechanical behavior of the disc were investigated. The model predicted that variations in implant modulus contribute less to the compressive disc mechanics compared to the implant geometrical parameters, for the ranges examined. It was concluded that some threshold exists for the nucleus implant modulus, below which little variations in load-displacement behavior were shown. Compressive biomechanics were highly affected by implant volume (under-filling the nucleus cavity, line-to-line fit, or over-filling the nucleus cavity) with a greater restoration of compressive mechanics observed with the over-filled implant design. This work indicated the effect of nucleus implant parameter variations on the compressive mechanics of the human lumbar intervertebral disc and importance of the "fit and fill" effect of the nuclear cavity in the restoration of the human intervertebral disc mechanics in compression. These findings may have clinical significance for nucleus implant design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device de...

متن کامل

Nucleus implant parameters significantly change the compressive stiffness of the human lumbar intervertebral disc.

Nucleus replacement by a synthetic material is a recent trend for treatment of lower back pain. Hydrogel nucleus implants were prepared with variations in implant modulus, height, and diameter Human lumbar intervertebral discs (IVDs) were tested in compression for intact, denucleated, and implanted condition. Implantation of nucleus implants with different material and geometric parameters into...

متن کامل

Design of an Elastic Arthroplastic Disc Optimized under Different Loads

Introduction: Due to limitations of current treatments for degenerative disc disease, arthroplastic methods to repair the diseased disc have been proposed. The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements following interbody fusion procedures. Because the success of artificial disc replacement depends on ...

متن کامل

Effects of Morphine Dependency on Intervertebral Disc in the Rat

Background: A large proportion of patients presenting with lumbar disc disease are opium addicts in our region. It was, therefore, hypothesized that morphine might affect the intervertebral disc. We investigated the histological findings of morphine dependency on intervertebral discs in rat. Methods: Forty NMRI adult male rats (230-250 g) placed on ordinary diet and received aqueous solution of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2009