Spectral multivariate calibration with wavelength selection using variants of Tikhonov regularization.
نویسندگان
چکیده
Tikhonov regularization (TR) is a general method that can be used to form a multivariate calibration model and numerous variants of it exist, including ridge regression (RR). This paper reports on the unique flexibility of TR to form a model using full wavelengths (RR), individually selected wavelengths, or multiple bands of selected wavelengths. Of these three TR variants, the one based on selection of wavelength bands is found to produce lower prediction errors. As with most wavelength selection algorithms, the model vector magnitude indicates that this error reduction comes with a potential increase in prediction uncertainty. Results are presented for near-infrared, ultraviolet-visible, and synthetic spectral data sets. While the focus of this paper is wavelength selection, the TR methods are generic and applicable to other variable-selection situations.
منابع مشابه
Model updating for spectral calibration maintenance and transfer using 1-norm variants of Tikhonov regularization.
In this study, calibration maintenance confronts the problem of updating a model developed in the primary condition to accurately predict the calibrated analyte in samples measured in new secondary conditions. Calibration transfer refers to updating a model based on a primary instrument to predict samples measured on new secondary instruments. A 2-norm variant of Tikhonov regularization (TR) ha...
متن کاملWavelength region selection and spectrophotometric simultaneous determination of naphthol isomers based on net analyte signal
Naphthol isomers were simultaneously and spectrophotometrically determined in wastewater, using a model based on net analyte signal (NAS). The calibration method used is a variation of the original hybrid linear analysis method as proposed by Goicoechea and Olivieri (HLA/GO). Owing to spectral interferences, the simultaneous determination of mixtures of naphthol isomers, using a spectrophotomet...
متن کاملImpact of standardization sample design on Tikhonov regularization variants for spectroscopic calibration maintenance and transfer
Multivariate spectroscopic calibration models are only valid to predict samples within the span of the calibration sample space measured relative to the current instrument environment (the primary conditions). Predicting samples in secondary conditions with new variances, same sample variances as the calibration space but a new instrument environment, or both, requires some form of continual mo...
متن کاملTomographic laser absorption spectroscopy using Tikhonov regularization.
The application of tunable diode laser absorption spectroscopy (TDLAS) to flames with nonhomogeneous temperature and concentration fields is an area where only few studies exist. Experimental work explores the performance of tomographic reconstructions of species concentration and temperature profiles from wavelength-modulated TDLAS measurements within the plume of an axisymmetric McKenna burne...
متن کاملNon-parametric calibration of the local volatility surface for European options
In this paper, we explore a robust method for calibration of the local volatility surface for European options. Assuming the the volatility surface is smooth, we apply a second order Tikhonov regularization to the calibration problem. Additionally we propose a new approach for choosing the Tikhonov regularization parameter. Using the TAPENADE automatic differentiation tool in order to obtain ad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied spectroscopy
دوره 64 12 شماره
صفحات -
تاریخ انتشار 2010