Comparison of static friction with self-ligating, modified slot design and conventional brackets

نویسندگان

  • Raquel Morais CASTRO
  • Perrin SMITH NETO
  • Martinho Campolina Rebello HORTA
  • Matheus Melo PITHON
  • Dauro Douglas OLIVEIRA
چکیده

OBJECTIVE To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA), with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA) and conventional (Kirium, Abzil, São José do Rio Preto, Brazil). The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA). The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil) with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. RESULTS There was a significant difference (p<0.05) in static friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (p<0.05). The angulation influenced friction (p<0.05) when the brackets were associated with a 0.018" wire. CONCLUSION Brackets with a modified slot design showed intermediate static frictional force values between the conventional and self-ligating brackets tested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

OBJECTIVE To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. MATERIAL AND METHODS Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric...

متن کامل

Third-order torque and self-ligating orthodontic bracket-type effects on sliding friction.

OBJECTIVE To examine the influence of third-order torque on kinetic friction in sliding mechanics involving active and passive self-ligating brackets. MATERIALS AND METHODS Wire-slot frictional forces were quantified and compared across five sets of brackets and tubes within a simulated posterior dental segment with -15 degrees , -10 degrees , -5 degrees , 0 degrees , +5 degrees , +10 degrees...

متن کامل

Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...

متن کامل

Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

STATEMENT OF THE PROBLEM Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. PURPOSE The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. MATERIALS AND METHOD The samples included 4 typ...

متن کامل

Frictional forces related to self-ligating brackets.

Orthodontic tooth movement can be regarded as teeth sliding on a wire like pearls on a string, the force being supplied by springs or elastics. The movement implies friction between wire and bracket, taking up part of the force and leaving an uncontrolled amount to act on the teeth. The friction is likely to depend on bracket construction and wire material. Therefore, in this investigation the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2013