Incidence and predictors of cognitive decline in patients with left ventricular assist devices.

نویسندگان

  • Timothy J Fendler
  • John A Spertus
  • Kensey L Gosch
  • Philip G Jones
  • Jared M Bruce
  • Michael E Nassif
  • Kelsey M Flint
  • Shannon M Dunlay
  • Larry A Allen
  • Suzanne V Arnold
چکیده

BACKGROUND After left ventricular assist device (LVAD) placement for advanced heart failure, increased cerebral perfusion should result in improved cognitive function. However, stroke (a well-known LVAD complication) and subclinical cerebral ischemia may result in transient or permanent cognitive decline. We sought to describe the incidence and predictors of cognitive decline after LVAD using a valid, sensitive assessment tool. METHODS AND RESULTS Among 4419 patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent LVAD implantation between May 2012 and December 2013, cognitive function was assessed in 1173 patients with the Trail Making B Test before LVAD and at 3, 6, and 12 months. The test detects several forms of cognitive impairment, including subclinical stroke. Cognitive decline was defined as a clinically important increase during follow-up using a moderate Cohen d effect size of 0.5×baseline SD (32 s). The cumulative incidence of cognitive decline in the year after LVAD implantation, treating death and transplantation as competing risks, was 29.2%. In adjusted analysis, older age (≥70 versus <50 years; hazard ratio, 2.24; 95% confidence interval 1.46-3.44; P(trend)<0.001) and destination therapy (hazard ratio, 1.42; 95% confidence interval, 1.05-1.92) were significantly associated with greater risk of cognitive decline. CONCLUSIONS Cognitive decline occurs commonly in patients in the year after LVAD and is associated with older age and destination therapy. These results could have important implications for patient selection and improved communication of risks before LVAD implantation. Additional studies are needed to explore the association between cognitive decline and subsequent stroke, health status, and mortality in patients after LVAD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...

متن کامل

Clinical psychological and neuropsychological issues with left ventricular assist devices (LVADs).

BACKGROUND Left ventricular assist devices (LVADs) are increasingly being used to treat patients in end-stage heart failure (HF) as bridge-to-transplantation, lifetime support or destination therapy. However, the importance of this newer technique for chronic cardiac support compared to heart transplantation is still open to discussion. To date, there are few studies that extensively explore th...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease

Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular quality and outcomes

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2015