Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.

نویسندگان

  • Roy Biran
  • David C Martin
  • Patrick A Tresco
چکیده

Implantable silicon microelectrode array technology is a useful technique for obtaining high-density, high-spatial resolution sampling of neuronal activity within the brain and holds promise for a wide range of neuroprosthetic applications. One of the limitations of the current technology is inconsistent performance in long-term applications. Although the brain tissue response is believed to be a major cause of performance degradation, the precise mechanisms that lead to failure of recordings are unknown. We observed persistent ED1 immunoreactivity around implanted silicon microelectrode arrays implanted in adult rat cortex that was accompanied by a significant reduction in nerve fiber density and nerve cell bodies in the tissue immediately surrounding the implanted silicon microelectrode arrays. Persistent ED1 up-regulation and neuronal loss was not observed in microelectrode stab controls indicating that the phenotype did not result from the initial mechanical trauma of electrode implantation, but was associated with the foreign body response. In addition, we found that explanted electrodes were covered with ED1/MAC-1 immunoreactive cells and that the cells released MCP-1 and TNF-alpha under serum-free conditions in vitro. Our findings suggest a potential new mechanism for chronic recording failure that involves neuronal cell loss, which we speculate is caused by chronic inflammation at the microelectrode brain tissue interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.

The influence of tethering silicon microelectrode arrays on the cortical brain tissue reaction was compared with that of untethered implants placed in the same location by identical means using immunoflourescent methods and cell type specific markers over indwelling periods of 1-4 weeks. Compared with untethered, freely floating implants, tethered microelectrodes elicited significantly greater ...

متن کامل

Chronic in vivo stability assessment of carbon fiber microelectrode arrays.

OBJECTIVE Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next...

متن کامل

Toward a comparison of microelectrodes for acute and chronic recordings.

Several variations of microelectrode arrays are used to record and stimulate intracortical neuronal activity. Bypassing the immune response to maintain a stable recording interface remains a challenge. Companies and researchers are continuously altering the material compositions and geometries of the arrays in order to discover a combination that allows for a chronic and stable electrode-tissue...

متن کامل

Response of brain tissue to chronically implanted neural electrodes.

Chronically implanted recording electrode arrays linked to prosthetics have the potential to make positive impacts on patients suffering from full or partial paralysis. Such arrays are implanted into the patient's cortical tissue and record extracellular potentials from nearby neurons, allowing the information encoded by the neuronal discharges to control external devices. While such systems pe...

متن کامل

Flexible polyimide microelectrode array for in vivo recordings and current source density analysis.

This work presents implantable, flexible polymer-based probes with embedded microelectrodes for acute and chronic neural recordings in vivo, as tested on rodents. Acute recordings using this array were done in mice under urethane anesthesia and compared to those made using silicon-based probes manufactured at the Center for Neural Communication Technology, University of Michigan. The two electr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental neurology

دوره 195 1  شماره 

صفحات  -

تاریخ انتشار 2005