Determination of polybrominated diphenyl ethers and polychlorinated biphenyls in human adipose tissue by large-volume injection-narrow-bore capillary gas chromatography/electron impact low-resolution mass spectrometry.

نویسندگان

  • Adrian Covaci
  • Boer Jacob de
  • John Jake Ryan
  • Stefan Voorspoels
  • Paul Schepens
چکیده

A new analytical method has been developed for the quantification of polybrominated diphenyl ethers (PBDEs) in human adipose tissue samples. After Soxhlet extraction and a cleanup procedure using two successive solid-phase extraction cartridges containing acid silica and acid silica: neutral silica:deactivated basic alumina (from top to bottom), detection can been achieved by narrow-bore (0.10-mm i.d.) capillary gas chromatography/electron impact low-resolution mass spectrometry using a large-volume injection technique. Using narrow-bore capillaries, it is possible to analyze complex mixtures in a short time (up to 10 min), saving 50% or more of the analysis time of conventional columns while maintaining a similar resolution power. The method allows the determination of five major PBDE congeners (BDE 28, 47, 99, 100, and 153) at concentrations below 1 ng/g lipid weight. Detection limits in the selected ion mode varied between 0.05 and 0.30 ng/g lipid weight, depending on the degree of bromination. The sensitivity of this method can compete with low-resolution mass spectrometry with electron capture ionization, while a much better selectivity is obtained. Levels of PBDEs in 20 Belgian human adipose tissue samples ranged between 2.18 and 11.70 ng/g lipid weight and were similar to previously reported values from Europe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and application of a simplified clean-up procedure for the determination of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in horse fat by gas chromatography-tandem mass spectrometry (GC-MS/MS).

A simplified clean-up procedure was developed in combination with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the determination of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in adipose tissue. Clean-up was performed by the successive application of a Mega Bond Elut silica column and a Bond Elut PCB column. Validation of the method was conducted ac...

متن کامل

Distribution of organobrominated and organochlorinated contaminants in Belgian human adipose tissue.

We have measured the levels of flame retardants, polybrominated diphenyl ethers (PBDEs), in 20 recent human adipose tissues from Belgium and compared them to other organohalogen compounds such as polychlorinated biphenyls (PCBs), hexachlorobenzene, 2,2-bis(4-chlorophenyl)-1,1,1-trichloroethane (p,p'-DDT), and its metabolite, 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene (p,p'-DDE). After Soxhlet...

متن کامل

Method development for the analysis of polybrominated diphenyl ethers, polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzo-furans in single extract of sediment samples.

A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PC...

متن کامل

Simultaneous determination of polybrominated diphenyl ethers and polychlorinated biphenyls by gas chromatography-tandem mass spectrometry in human serum and plasma.

Sensitive and reliable methods for simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in limited volumes of human serum or plasma need to be further documented especially when they accumulate at low levels that are still capable of disrupting endocrine and immune functions, and affecting neurodevelopment and reproduction. The objective of t...

متن کامل

Study of the retention behaviour of monofluorinated analogues of Polybrominated Diphenylethers (F-PBDEs) in gas chromatography

Introduction Polybrominated diphenyl ethers (PBDEs) are globally distributed in the environment. They have been used as flame retardants for over 2 decades [1]. PBDEs have been found to bioaccumulate and there is also a concern about the health effects of PBDE exposure due to their potential endocrine disrupting properties. PBDEs are structurally similar to polychlorinated biphenyls (PCBs) and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 4  شماره 

صفحات  -