Design and calibration of a compact multi-frequency EIT system for acute stroke imaging.

نویسندگان

  • A McEwan
  • A Romsauerova
  • R Yerworth
  • L Horesh
  • R Bayford
  • D Holder
چکیده

A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT imaging of the head. Improvements include increased input and output impedances, increased bandwidth and improved CMRR (80 dB) and linearity over frequencies and load (0.2% on a single channel, +/-0.7% on a saline tank over 20 Hz-256 kHz and 10-65 Omega). The accuracy of the system is sufficient to image severe acute stroke according to the specification from recent detailed anatomical modelling (Horesh et al 2005 3rd European Medical and Biological Engineering Conference EMBEC'05). A preliminary human study has validated the main specifications of the modelling, the range of trans-impedance from the head (8-70 Omega) using a 32 electrode, 258 combination protocol and contact impedances of 300 Omega to 2.7 kOmega over 20 Hz to 256 kHz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Impedance Tomography System for detecting fast physiological signal: KHU Mark2.5

Electrical impedance Tomography (EIT) can produce real-time images of conductivity variations associated with respiratory and cardiac cycles. We report the development of a new multi-frequency EIT system called the KHU Mark2.5. It has new features such as flexible electrode configurations to accommodate application-specific requirements, multiple independent current sources and voltmeters for f...

متن کامل

Performance improvements in a MF-EIT system for acute stroke: The UCL Mk2.5

A recently developed EITS system, the UCLH mk2.5 was tested on a resistor phantom and in linear time and frequency difference imaging of a cylindrical tank, 10cm diameter, filled with 0.1% saline, and 16 electrodes in a ring; the test object was a cylinder of banana, 2 cm long and 1 cm in diameter. Reproducible images with the same location as the test object were obtained with both methods. No...

متن کامل

Calibration methods for a multi-channel multi-frequency EIT system.

Multi-channel multi-frequency electrical impedance tomography (EIT) systems require a careful calibration to minimize systematic errors. We describe novel calibration methods for the recently developed KHU Mark1 EIT system. Current source calibration includes maximization of output resistance and minimization of output capacitance using multiple generalized impedance converters. Phase and gain ...

متن کامل

Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of an analysis method and calibration.

MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data we...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2006