Evaluation of Cobas TaqMan MTB PCR for detection of Mycobacterium tuberculosis.
نویسندگان
چکیده
Nucleic acid-based amplification tests allow the rapid detection of Mycobacterium tuberculosis. Recently, a real-time PCR assay for M. tuberculosis complex, the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), was introduced. We performed a prospective study to evaluate the diagnostic performance of the Cobas TaqMan MTB test system. A total of 406 specimens collected from 247 patients were simultaneously tested by conventional culture, Cobas Amplicor MTB PCR, and TaqMan MTB PCR. The cross-reactivity with other Mycobacterium species and the detection limit were also evaluated. Among 406 specimens, a total of 24 specimens (5.9%) were culture positive: 14 specimens were positive by both TaqMan and Amplicor MTB PCRs, while 5 specimens were positive by only TaqMan PCR. The remaining five specimens were negative by both PCR methods. Seven specimens with negative culture results were positive by TaqMan PCR, but five of these were negative by Amplicor MTB PCR. The sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were 79.1%, 98.2%, 73.1%, and 98.7% for TaqMan and 58.3%, 99.5%, 87.5%, and 97.4% for the Amplicor MTB PCR test, respectively. There was no cross-reactivity with M. tuberculosis and nontuberculous mycobacterial species. The detection limit for the Cobas TaqMan MTB PCR test was 4.0 copies/μl. The Cobas TaqMan MTB PCR test showed higher sensitivity for detection of the M. tuberculosis complex without disturbing the specificity and NPV than the Amplicor MTB PCR test.
منابع مشابه
Comparison of AdvanSure TB/NTM PCR and COBAS TaqMan MTB PCR for Detection of Mycobacterium tuberculosis Complex in Routine Clinical Practice
The AdvanSure tuberculosis/non-tuberculous mycobacterium (TB/NTM) PCR (LG Life Science, Korea) and COBAS TaqMan Mycobacterium tuberculosis (MTB) PCR (Roche Diagnostics, USA) are commonly used in clinical microbiology laboratories. We aimed to evaluate these two commercial real-time PCR assays for detection of MTB in a large set of clinical samples over a two-year period. AdvanSure TB/NTM PCR an...
متن کاملEvaluation of Cobas TaqMan MTB for direct detection of the Mycobacterium tuberculosis complex in comparison with Cobas Amplicor MTB.
The Roche Cobas Amplicor MTB assay, recently replaced by the Roche Cobas TaqMan MTB assay, was one of the first commercially available assays for detection of the Mycobacterium tuberculosis complex based on nucleic acid amplification. We reported previously on the limited specificity of the Cobas Amplicor MTB assay, in particular for positive samples with an optical density at 660 nm (OD660) of...
متن کاملEvaluation of the Cobas TaqMan MTB test for direct detection of Mycobacterium tuberculosis complex in respiratory specimens.
The Cobas TaqMan MTB test, based on real-time PCR technology, was evaluated for direct detection of Mycobacterium tuberculosis complex (MTBC) in respiratory specimens. A total of 1,093 samples from 446 patients, including 118 acid-fast smear-positive and 975 acid-fast smear-negative specimens, were investigated. Diagnostic cultures performed with 7H11 agar, Löwenstein-Jensen medium, and the Bac...
متن کاملIs real-time PCR better than conventional PCR for Mycobacterium tuberculosis complex detection in clinical samples?
Cobas Amplicor MTB and later Cobas TaqMan MTB were used to test a very large series of consecutive specimens received for tuberculosis diagnosis. Performance parameters were estimated and compared overall and for separate specimen categories. Both systems showed excellent specificity, and that of TaqMan was the higher. The sensitivities were similar but satisfactory only with respiratory specim...
متن کاملComparison of two molecular methods for rapid diagnosis of extrapulmonary tuberculosis.
Application of real-time PCR for the detection of Mycobacterium tuberculosis enables results to be obtained in about 2 h. A total of 340 nonrespiratory samples were processed using two real-time PCR assay kits: Xpert MTB/RIF and Cobas TaqMan MTB. The sensitivity and specificity of the Xpert assay were 95% and 100%, respectively, compared to 78% and 98% for the Cobas assay.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 49 1 شماره
صفحات -
تاریخ انتشار 2011