In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals

نویسندگان

  • Koray Yılmaz
  • Gülşah Uslu
  • Taha Özyürek
چکیده

Objectives It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. Materials and Methods 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). Results In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). Conclusions Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Cyclic Fatigue Resistance of ProGlider and One G Glide Path Files.

INTRODUCTION The aim of this study was to compare the cyclic fatigue resistances of nickel-titanium rotary glide path files, which are manufactured as single-file systems, under dynamic model. METHODS Twenty ProGlider (16.02) and 20 One G (14.03) nickel-titanium glide path files were included in this study. Cyclic fatigue tests were performed with specifically manufactured dynamic cyclic test...

متن کامل

In vitro Evaluation of Cyclic Fatigue Resistance of Reciprocating and Rotary Single-file System

Aim: In vitro study evaluation of the cyclic fatigue resistance of reciprocating and rotary single-file system [Wave One Gold (WOG), Reciproc, Hyflex electrical discharge machining (EDM) file systems] utilizing cyclic fatigue testing device. Materials and methods: Three nickel–titanium rotary systems (Hyflex EDM size #25, 0.06 taper and Reciproc and WOG size #25, 0.06 taper) were used in this s...

متن کامل

Comparison of the centering ability of Wave·One and Reciproc nickel-titanium instruments in simulated curved canals

OBJECTIVES The aim of this study was to evaluate the shaping ability of newly marketed single-file instruments, Wave·One (Dentsply-Maillefer) and Reciproc (VDW GmbH), in terms of maintaining the original root canal configuration and curvature, with or without a glide-path. MATERIALS AND METHODS According to the instruments used, the blocks were divided into 4 groups (n = 10): Group 1, no glid...

متن کامل

An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

AIM To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. METHODOLOGY The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination,...

متن کامل

Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.

AIM To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled. METHODOLOGY Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2017