Interstitial brachytherapy guided intensity modulated radiation therapy (IBGIMRT) in cervical cancer: a dosimetric study

نویسندگان

  • Daya Nand Sharma
  • V. Subramani
  • Goura Kisor Rath
  • K. S. Jothybasu
  • Amit Bahl
  • Parmod Kumar Julka
  • N. Gopishankar
چکیده

PURPOSE Interstitial brachytherapy (IBT) is used as an alternative to intracavitary radiotherapy in the management of cervical carcinoma. We have devised a new technique called interstitial brachytherapy guided intensity modulated radiotherapy (IBGIMRT) which can potentially reduce doses to organs at risk (OaRs). It utilizes IMRT planning on the target volume (TV) defined by implantation of IBT needles. This study compares the dosimetry of IBT and IBGIMRT. MATERIAL AND METHODS CT scan images of 18 patients with cervical cancer, who have been already treated by HDR-BT, were used to generate two rival plans, IBT and IBGIMRT, for a prescription dose of 10 Gy. Following dosimetric factors were used for comparison: volume receiving 95% of prescription dose (V95), conformity index (COIN) and external volume index (EI) for target and for OaR, dose received by volume of 1 cm3 (D1cc), 2 cm3 (D2cc), 5 cm3 (D5cc) and also volume receiving 50% and 75% of prescription dose (V50 and V75). RESULTS The two plans resulted in COIN difference of 49.8% (p < 0.0001) and EI difference of 36.4% (p < 0.0028) in favor of IBGIMRT. Mean D1cc, D2cc and D5cc values for bladder were 8.3 Gy, 7.6 Gy and 6.4 Gy; and 7.8 Gy, 7.3 Gy and 5.8 Gy with IBT and IBGIMRT, respectively (p > 0.05). Similar figures for rectum with IBT vs. IBGIMRT were 11.2 Gy vs. 7.02 Gy, 10.5 Gy vs. 6.4 Gy and 9.1 Gy vs. 4.8 Gy respectively (p < 0.01). CONCLUSIONS Our novel technique, IBGIMRT, has shown its dosimetric superiority and therefore needs to be studied in clinical set up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy and toxicity of image-guided intensity-modulated radiation therapy combined with dose-escalated brachytherapy for stage IIB cervical cancer

Considering internal organ motion and tumor regression, it is controversial to use intensity-modulated radiation therapy (IMRT) in definitive radiotherapy for cervical cancer. In this study, we evaluated the efficacy and toxicity of IMRT combined with dose-escalated intracavitary brachytherapy (ICBT) for cervical cancer. In total, 373 consecutive FIGO-stage-IIB cervical cancer patients treated ...

متن کامل

Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer

PURPOSE The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT) combined with high-dose-rate (HDR) intracavitary brachytherapy (ICBT) to improve dose distribution in cervical cancer treatment. MATERIAL AND METHODS For 42 cervical cancer patients, magnetic resonance imaging (MRI) scans were acquired after completion of whole...

متن کامل

Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study

PURPOSE To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. METHODS Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously tr...

متن کامل

Intensity-modulated radiotherapy combined with iodine-125 seed implantation in non-central recurrence of cervical cancer: A case report and literature review

Recurrent cervical cancer is a clinically complex disease that is difficult to treat. There are numerous treatment options, but the results achieved by each are poor. External-beam radiation therapy of the pelvic lymph drainage area, in combination with intracavitary afterloading or the interstitial implantation of a radiation source (i.e., brachytherapy), are the current standard radiotherapy ...

متن کامل

Dosimetric study for cervix carcinoma treatment using intensity modulated radiation therapy (IMRT) compensation based on 3D intracavitary brachytherapy technique

PURPOSE Intensity modulated radiation therapy (IMRT) compensation based on 3D high-dose-rate (HDR) intracavitary brachytherapy (ICBT) boost technique (ICBT + IMRT) has been used in our hospital for advanced cervix carcinoma patients. The purpose of this study was to compare the dosimetric results of the four different boost techniques (the conventional 2D HDR intracavitary brachytherapy [CICBT]...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009