Performance Evaluation of Counter·flowwet Cooling Towers Using Exergetic Analysis

نویسندگان

  • A. Ataei
  • M. H. Panjeshahi
  • M. Gharaie
چکیده

In this paper, performance evaluation of wet cooling tower is done. To achieve this aim, first, thermal behavior of counter-flow wet cooling tower is studied through a simulation model. The influence of the environmental conditions on the thermal efficiency of the cooling tower is investigated. The cooling tower performance is simulated in terms of varying air and water temperatures, and of the ambient conditions. This model allows the use of a variety of packing materials. Second, the exergetic analysis is applied to study the cooling tower potential of performance improvement. The model is validated against the experimental data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On thermal performance of seawater cooling towers

Seawater cooling towers have been used since the 1970’s in power generation and other industries, so as to reduce the consumption of freshwater. The salts in seawater are known to create a number of operational problems including salt deposition, packing blockage, corrosion, and certain environmental impacts from salt drift and blowdown return. In addition, the salinity of seawater affects the ...

متن کامل

Thermodynamic Modelling and Exergtic Analysis of Ammonia-water Refrigeration System

In this study, the first and the second laws of thermodynamics (exergetic analysis) are used to analyse the performance of a single stage ammonia-water absorption cooling system operating under different working conditions. In this analysis, the performance of the system is simulated under various operating temperatures: the condenser and absorber (30 and 40°C), evaporator (-10°C, 0°C and +10°C...

متن کامل

Effect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition

Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...

متن کامل

Reuse of Refinery Treated Wastewater in Cooling Towers

In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...

متن کامل

Saving Energy by Exergetic Analysis of MTP Process Refrigeration System

The exergetic analysis is a tool that has been used successfully in many studies aiming a more rational energy consumption to reduce the cost of processes. With this analysis, it is possible to perform an evaluation of the overall process, locating and quantifying the degradation of exergy. This paper applies exergy approach for analyzing the heat exchanger network design and refrigeration of M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -