Transient forces generated by projectiles on variable quality mouthguards monitored by instrumented impact testing.
نویسندگان
چکیده
OBJECTIVES (a) To determine the force-time trace that occurs when a spring mounted simulated upper jaw is impacted; (b) to examine if mouthguards of variable quality have significant influence on such force-time traces; (c) to attempt to relate physical events to the profile of the force-time traces recorded. METHODS A simulated jaw, consisting of ceramic teeth inserted into a hard rubber arch reinforced with a composite jawbone, was fitted with various mouthguards as part of a previous round robin study. A clinical assessment distinguished good, bad, and poor mouthguards, and these were each fitted to the jaw, which was then submitted to instrumental impact tests under conditions expected to produce tooth fractures. The force-time trace was recorded for such impact events. RESULTS The spring mounting method caused two distinct peaks in the force-time trace. The initial one was related to inertia effects and showed an increase in magnitude with impactor velocity as expected. The second peak showed features that were related to the differences in the mouthguards selected. CONCLUSIONS The use of a force washer within a conical ended impactor enabled force-time traces to be recorded during the impact of a spring mounted simulated jaw fitted with mouthguards of variable quality. The spring mounting system causes an initial inertial peak followed by a second peak once the spring mount has fully compressed. Good fitting guards, which keep most teeth intact, result in high stiffness targets that in turn generate high reaction forces in the impactor. If the spring mounting is omitted, the two peaks are combined to give even higher reaction forces. The force-time trace offers some potential for assessing both overall mouthguard performance and individual events during the impact sequence. Mouthguards with good retention to the jaw remained attached during the impact event and helped to preserve the structural integrity of the target. This in turn developed high forces in the second part of the force-time trace. Guards that detached during impact and allowed tooth fractures showed lower forces in the second part of the test. The force profile measured offered some quantitative support to, and agreement with, the observed clinical quality of the mouthguards.
منابع مشابه
In-vitro Force Assessments of an Autoclavable Instrumented Sternal Retractor
It is well known that median sternotomy might lead to rib and/or sternum micro/macro-fractures and/or brachial plexus injuries, eventually resulting in chronic pain with significant impact on patient’s quality life.Postoperative chronic pain is recognized as a multifactorial complex issue, it has been assessed that excessive sternum retraction forces can be considered one of these factors. On t...
متن کاملNumerical Simulation of Impact of Low Velocity Projectiles With Water Surface
In this article, Finite Element Method (FEM) and Eulerian-Lagrangies Algorithm (ELA) formulation were used to numerically simulate the impact of several low-velocity projectiles with water surface. Material models which were used to express behavior of air and water included Null material model. For the projectiles, rigid material model were applied. Results were validated by analyzing the impa...
متن کاملLightweight Automatic Error Detection by Monitoring Collar Variables
Although proven to be an effective way for detecting errors, generic program invariants (also known as fault screeners) entail a considerable runtime overhead, rendering them not useful in practice. This paper studies the impact of using simple variable patterns to detect the so-called system’s collar variables to reduce the number of variables to be monitored (instrumented). Two different patt...
متن کاملAnalytical and numerical modeling of erosive projectiles into steel fiber reinforced concrete target
In this paper, modeling of high speed projectiles with different nose shapes, penetrating into steel fiber reinforced concrete is investigated. This is a novel study because it considers the length to diameter ratio of steel fiber as well as projectile length to diameter ratio and volume fraction of fiber used in concrete matrix on the impact resistance of steel fiber reinforced concrete fibers...
متن کاملRelationship between temporomandibular joint dynamics and mouthguards: feasibility of a test method.
A test system was developed establishing the feasibility of collecting biomechanical data as they relate to the use of mouthguards. Previous experimental studies have examined the physical and mechanical properties of mouthguard materials. This information has been used as a guide for establishing material standards and specifications for the fabrication of mouthguards, but it lacks the key bio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of sports medicine
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2001