Susceptibility artifact correction in GE images
نویسندگان
چکیده
In Gradient Echo (GE) images, susceptibility artifact induces both intravoxel dephasing and pixel shifting (Fig. 2-a) leading to intensity and geometric distortions [1] that may disturb image analysis. In previous works, correction of GE images is assessed by modifying acquisition parameters or by using specific sequences [2]. All the proposed techniques always constrain the acquisition process and a trade-off has to be found with the initial imaging goal. So far, there is no image processing existing method. In this work, we propose an original image-processing based correction method for susceptibility artifact in GE MR Images when a field map of the imaged object is known. Susceptibility artifact impact is modeled by means of a pixel shifting map and an intensity distortion map. The intensity distortion map which takes into account different complex phenomena is obtained through MRI simulation.
منابع مشابه
Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملQualitative evaluation of Chang method of attenuation correction on heart SPECT by using custom made heart phantom
SPECT detects γ-rays from administered radiopharmaceutical within the patient body. γ-rays pass through different tissues before reaching detectors and are attenuated. Attenuation can cause artifacts; therefore different methods are used to minimize attenuation effects. In our study efficacy of Chang method was evaluated for attenuation purpose, using a custom made heart phantom. Due to d...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملCorrection Accuracy in B1 measurement for high field Image Intensity Correction
H. Kabasawa, C. Guclu, Z. Li Applied Science Laboratory Japan, GE Yokogawa Medical Systems, Hino-shi, Tokyo, Japan, GE Healthcare-Technologies, 3200 Grandview Blvd, Waukesha, WI, United States [Introduction] MR imaging with phased array receive coils became available at 3T and higher field strengths. In lower field strength systems, uniformity correction methods using body coil image as homogen...
متن کامل